Arton ASD-10QR Manual de instrucciones

Navegue en línea o descargue pdf Manual de instrucciones para Alarma de humo Arton ASD-10QR. Arton ASD-10QR 1 páginas. Wireless interconnectable smoke alarm with a built-in 10-year 3v battery

Instruction manual
WIRELESS INTERCONNECTABLE SMOKE ALARM WITH A WITH BUILT-IN 10-YEAR 3V BATTERY
Model: ASD-10QR
EN14604:2005/AC 2008
Essential characteristics:
Nominal activation conditions/sensitivity, response delay (response
1134
Fito Products BV
Operational reliability:
De Langkamp 12a
Tolerance to supply voltage:
Durability of operational reliability and response delay, temperature
The Netherlands
resistance:
17
Durability of operational reliability, vibration resistance:
Optical smoke detector,
Durability of operational reliability, humidity resistance:
alerts you in the event
Durability of operational reliability, corrosion resistance:
suitable for residential
Durability of operational reliability, electrical stability:
buildings.
RETAIN THESE INSTRUCTIONS FOR FUTURE USE!
These instructions contain important information for correct instal-
lation and use of your smoke detector. Please read this informa-
tion carefully and retain these instructions for future
reference.
SAFETY ISSUES:
• Do not paint to the smoke alarm and do not cover it.
• Never install smoke detectors in rooms with a high humidity, such
as bathrooms, showers, kitchens and saunas.
• Test your smoke alarm regularly, once a month and always after
a period of absence. Test by pressing the test button for at least 2
seconds, a loud alarm will follow. Keep a distance of at least 50 cm.
between the alarm and your ears.
• Never open the smoke alarm, this will invalidate the warranty.
• Do not test with smoke directly after instalation, wait at least 1 hour.
IMPORTANT INFORMATION
Correct usage will ensure you have valuable extra
time to escape. Every correctly installed smoke detec-
tor will increase your potential escape time.
• A smoke detector is not a fire-prevention
measure.
• Install the smoke detector in the correct place, if
possible in the middle of the ceiling.
WARNING: Read carefully chapter "Never fit a
smoke detector"
• Keep the smoke detector out of the reach of
children.
• Test the unit on a monthly basis and after a
period of absence. When the alarm does not sound,
have your smoke alarm inspected by the service
point or when the smoke alarm is more than 10
years old discard the alarm.
CAUTION: Never test with fire!
• Clean the detector regularly (once a month) using
the soft brush from a vacuum cleaner. In addition
the smoke alarm can also be cleaned using a moist
cloth.
• If the detector emits a beeping sound every 40
seconds, this means that the battery is nearly flat
and that you should replace the smoke detector.
• The lifespan of smoke detectors is 10 years.
• A false alarm can be silenced by pressing the test
and silence button.
• You can make your Model ASD-10Q smoke detec-
tor less sensitive for 10 ± 2 minutes by
pressing the test button shortly. The detector will
nonetheless sound the alarm if the quantity of
smoke is too significant.
• You can also test and switch on the hush feature by
using the ASD-RRC. This is the optionally available
wireless remote control.
IMPORTANT INFORMATION IN CASE OF
ALARM IN THE EVENT OF A FIRE
• Plan TWO escape routes and practice these with all
members of the family.
• Agree upon a location, where everyone goes to in
case of a fire.
In the event of a fire:
• Leave the building immediately and go to the
agreed location.
• Make sure everyone has left the building.
• Close the doors behind you and never open a warm
door. In case of a warm door, choose a different
escape route.
• In the event of considerable build-up of smoke,
crawl out of the building keeping as close to the
floor as possible.
• Wherever possible, breathe through a cloth (prefera-
bly moist), or else hold your breath as much as you
can. The majority of deaths and injuries are caused
by smoke inhalation rather than fire itself.
• Call the fire brigade outside or at the neighbours.
• NEVER go back into a burning building.
• Additional information can be obtained at the local
fire department.
SPECIFICATIONS:
RF frequency:
868.100 (<1% duty cycle)
RF Codes:
65535
RF Power:
+14 dBm max
Battery life:
10 years under normal
conditions
Battery type:
Sealed, Lithium, AA, 3V
Operating temperature: 0ºC tot + 55ºC
Alarm sound level:
>85dB op 3 meter
Hush time:
10 ± 2min.
AR 3V BATTERY
17
EN14604:2005/AC 2008
vfdb 14/01
1134-CPR-199
DoP no: 10QR16
RED
Performance:
Passed
Passed
Passed
Passed
Passed
Passed
Passed
Passed
Ceiling mount
Battery powered
Battery lifetime 10 years
Individual Alarm Indicator
Alarm silence facility
Suitable for installation in a
caravan
Wireless interconnectable up
to 24 pcs.
POSITIONING THE SMOKE DETECTOR
RECOMMENDED LOCATIONS:
bedroom
kitchen
bathroom
bedroom
hallway
bedroom
bedroom
living room
figure 1
bedroom
hallway
kitchen
hallway
Optimal protection:
In all occupied areas such as bedrooms, living room,
study and the escape route as hallway, basement
and attic.
Maximum protection:
- Smoke detector in all rooms (with the exception
of bathrooms, kitchen, garages, etc.)
- Heat detectors can be installed in bathrooms,
kitchens, airing cupboards, utility rooms, etc.
• The smoke detector should preferably be installed
in the middle of the ceiling, at least 50 cm from the
wall.
• In the case of pitched roofs, install the smoke detec-
(measured vertically) from the ridge of the roof.
• Ensure that the detector can always be reached for
testing and cleaning.
Never fit a smoke alarm:
• In bathrooms, kitchens, shower rooms, garages,
etc. Places where a smoke detector may go off
needlessly due to condensation, normal smoke or
gases. A smoke detector should be fitted at least 5
metres from such sources of smoke.
place, etc.
• In the vicinity of (or adjacent to) decorative objects,
doors, sockets, lights, fittings, windows, wall
ventilators, etc. which could mean that smoke does
not reach the smoke detector. Minimum 50cm
away.
• Surfaces that are usually warmer or colder than the
rest of the room. Differences in temperature can
prevent smoke from reaching the detector.
• Adjacent to or directly above stoves or heaters.
• In very high or difficult to reach places. This makes
it hard to reach the detector to test or clean it.
• In very dusty or dirty places. Accumulation of dust
will prevent smoke from reaching the smoke cham-
ber and in time will lead to a false alarm.
• Within 1 metre of dimmer switches and wiring. Some
dimmer switches can trigger a fault in the detector.
• Within 1.5 metres of fluorescent lights. Electrical
impulses can adversely affect the functioning of the
detector.
• Outdoors and in spaces where a large number of in-
sects are found. Small insects in the unit's detection
chamber can disrupt the functioning of the detector.
The labels on the rear side of the detector contain
important information.
HOW TO USE THE ASD-10QR:
Wireless interconnecting the smoke alarms:
The ASD-10QR is a wireless device. Each smoke
alarm can be the sender or the receiver.
To interconnect a few smoke alarms the unique RF
code must be generated in one of them and set to
the others All ASD-10QR smoke alarms in a house,
apartment or property should be set to the same RF
Code.
It is not recommended to interconnect more than 24
smoke alarms.
Generating the unique RF Code:
• Remove all smoke alarms from bases.
• Press and hold the test button for about 4 sec. on
one of them (randomly chosen) and release the
button when the red LED will lit. This smoke alarm
(Master) has chosen one of the 65.535 possible RF
codes. The red LED on the Master will be lit until
the interconnect procedure is over.
• In order to set the generated code to the other
smoke alarms(Slaves) push the Test button on
each of them. The successful setting of the code to
the Slave will be accompanied with blinking of the
red LED. You have two minutes to inter connect all
smoke alarms, after two minutes the red LED will
extinguish indicating that the interconnect proce-
dure has ended.
• To end the interconnect procedure you can also
press the test button on the Master or fasten the
Master on to the base. The red LED will extinguish
indicating that the interconnect procedure has
ended.
How to disconnect a smoke alarm:
If you need to disconnect one smoke alarm carry out
Generating the unique RF Code procedure.
YES
How to add a smoke alarm:
YES
To add a smoke alarm you need to carry out the Ge-
nerating the unique RF Code procedure on all the
YES
smoke alarms you want to interconnect.
YES
Testing the smoke alarms and the interconnec-
tion:
YES
Install all interconnected smoke alarms to bases.
Press and hold on the Test button on one of them
(Test mode). After the period of 10 to 30 sec. all
NO
interlinked smoke alarms will go to the Remote Alarm
mode. Upon releasing the Test button, the other
YES
alarms will stay in the Remote Alarm for 5-10 sec.
The installation:
1. Choose a location that satisfies the conditions as
described in: Positioning the smoke detector.
2. Remove the base plate of the detector by turning
the base plate anticlockwise (to the left).
3. Mark the mounting holes in the base plate and
drill the holes (use a 6 mm drill). If you do not
use the dowels, then use a 3 mm drill. Screw the
base plate securely onto the ceiling. Make sure
that the base plate is tight
against the ceiling so that
no air circulation above the
smoke alarm is possible,
which could impede smoke
detection.
figure 2
If the opening is too large,
this must be remedied by
the use of a filler.
If you use the double sided
bedroom
tape, make sure the base
and the surface you want
to install the smoke alarm
is grease free. Attach the double sided tape to the
living room
base and then the base to the ceiling.
4. Place the smoke detector on the base and turn it
until the smoke detector clicks into the base. Turn
Basement
the smoke detector clockwise to secure the smoke
detector and activate it. A melody will sound to
confirm the activation.
5. Test your smoke alarms by following the
procedure as described in chapter: "Testing
the smoke alarms and the interconnection"
ATTENTION: The smoke alarm should be covered
or temporarily removed during renovation work or
structural alterations. Once the day's work is com-
plete, clean the smoke detector with the soft brush
from a vacuum cleaner and then activate it again.
Always test it by pressing the test button once it has
been reinstalled.
WARNING: covering the smoke alarm causes loses
its functionality.
WARNING: Do not paint the smoke alarm. Also
FUNCTION AND MEANING OF LIGHT AND SOUND SIGNALS:
Sound signal:
No signal
Long pulsating sound
Long lingering sound
1 short signal every 40 sec.
2 short signals every 4 hour
3 short signals every 40 sec.
No signal
No signal
Long pulsating sound while
pressing the test button.
3 short signals while pressing
the test button.
• When the ASD-10QR is removed from the base (disconnected) after detecting a problem, it gives the
sound that belongs to the detected problem.
• The remaining connected ASD-QR smoke alarms will sound two beeps on disconnection (removal from
base), up to 4 hours after removal of the ASD-10QR with a battery empty indication.
CAUSES OF FALSE ALARM
The smoke detector can be activated by steam, con-
densation, dust, smoke and small insects. These are
to be prevented as much as possible. See chapter
"Never fit a smoke alarm". If a smoke alarm fre-
quently gives a false alarm, it might be necessary to
install the detector in another location.
Additional information can be found on our website
tioning correctly, contact your supplier or
MAINTENANCE
• Test your smoke alarm regularly, once a month and
always after a period of absence. See "Testing the
smoke alarms and the interconnection"
• Clean the detector regularly (once a month) using
the soft brush from a vacuum cleaner. In addition
the smoke alarm can also be cleaned using a moist
cloth.
• Never allow the detector to come into contact with
LIMITATIONS OF SMOKE DETECTORS
In countries where they are commonly in use, smoke
detectors have contributed to reducing deaths and
injuries. Independent bodies have established that
they were insufficient in around 35% of fires, namely
in the following situations:
• Where the battery had been removed or was not
working. For that reason, you should test the unit
regularly.
• Where smoke is not able to reach the detector in
the event of a fire, meaning the unit cannot be set
off. Examples include a fire on another floor where
there is no smoke detector, a fire behind closed
doors, a fire in a chimney or smoke being blown
away from the detector. For that reason, smoke
detectors are recommended in all rooms, or at any
rate on every floor.
• Where the alarm is not heard. A person may not be
woken by the alarm if that person had consumed
excess alcohol and/or drugs.
• A few fires are not always detected on time, e.g.
smoking in bed, if there is no smoke detector in the
bedroom. In the case of escaping from gas or
violent explosions, improperly storing explosive pro-
ducts and flammable liquids (petrol, paint, methyla-
ted spirit, etc.), electrical faults, acids, children
playing with matches (fire).
• The lifespan of smoke detectors is 10 years.
PRODUCT WARRANTY
If used and maintained properly, the manufacturer
guarantees this product against material and/or
manufacturing defects for a period of 5 years from the
original date of purchase. This guarantee only applies
if the smoke detector is activated within 14 months
after the production date. Exceptions include damage
arising from accidents or misuse. If the product
becomes defective within the stated period, then it will
be repaired or replaced free of charge. Please do not
open the smoke alarm or attempt to repair the
Mounting holes:
product yourself or tinker with it, which will invalidate
the warranty.
WARNING: Unscrewing the smoke alarm invalidates
the warranty.
DOP (Declaration of Performance)
The DoP can be downloaded on our website www.
fito.eu
INSTRUCTIONS FOR REMOVAL
Do not dispose of your old detector in
Base
the bin, but rather hand it in to a local col-
lection point for small, domestic waste.
EUROPEAN SUPPLIER:
Fito Products BV
De Langkamp 12a
WIJK BIJ DUURSTEDE
Nederland
[email protected] - www.fito.eu
figure 4
red LED
Red LED:
Function:
Flashes every
Standby mode
320 sec.
Periodical automatic self-diagnostics
Flashes every
Alarm status
0.5 sec.
Non
1 of the interconnected smoke alarms are in alarm
Non
Low battery signal. The smoke alarm needs to be
replaced.
Non
Low battery signal in one of the interconnected smoke
alarms. This smoke alarm needs to be replaced.
Non
Fault/ smoke chamber contamination
Flashes every
The smoke chamber has been abruptly contaminated
0.5 sec.
and needs to be cleaned.
Flashes every
HUSH mode (Alarm muting, sensitivity reduction)
10 sec.
Flashes every
Test mode: De smoke alarm is operates correctly. All
0.5 sec.
interconnected and installed to the base smoke alarms
will go to Remote Alarm status in 10 - 30 sec.
Flashes every
De smoke alarm does not operate correctly and needs
3 sec.
to be replaced.
-
Test/hush
button
versie 1 2021-6