Artopex e-Motion Manual del usuario - Página 5
Navegue en línea o descargue pdf Manual del usuario para Mobiliario interior Artopex e-Motion. Artopex e-Motion 10 páginas. Two-leg adjustable table
Error Codes / Troubleshooting
If the LCD Controller displays error codes when raising or lowering the work surface, a reset will be
required.
E01, E02, E03, E04 - Motor error
Control box can not detect motor halt plate signal or Control box detects one lifting column is
overloaded. This is a safety protection.
Please remove any large loads from the work surface and reset the controller. If the error code still
appears, make sure the Patch Cord (see Componentd Diagram, page 3) is properly connected (unplug
and reconnect the wire) and perform the reset procedure again. If the error code is still there, please
contact our customer service department for technical assistance.
HOT - Control box temperature protection
This indicates that the control box temperature is above 75º celcius or the system has been in
continuous use for 2 minutes or more. The lifting columns are locked out for up to 18 minutes as a safety
precaution (to lower the system's temperature). For an urgent reset, unplug & replug the power cord.
E06 - Asynchronous protection
Lifting columns are at different heights, more than 10mm, reset required.
E07 - Overload protection
Desk load in excess of 113 kg, user needs to reduce load, then wait for 3 seconds (the Reset procedure
can also be done).
E08 - Low voltage protection
Power voltage is too low for the controller. This is a safety cut out protection, system will recover as
soon as voltage returns to normal.
E09 - High voltage protection
Power voltage is too high for the controller. This is a safety cut out protection, system will recover as
soon as voltage returns to normal
E10 - Control Box or Keypad issue
If error code E10 appears and remains even after having done the Reset procedure, it is possible the
Control Box or the Keypad is defective, please contact our customer service department.
Also check if the problem is due to a damaged Patch Cord by plugging both lifting column cables
directly into the Control Box.