10.
AD Conversion (ARTCAM-WOM series)
10.1.
Standard functions (configurable in standard viewer/SDK)
・Digital gain
Global gain (digital gain) can be configured with the standard viewer software or SDK.
Setting range on standard viewer software: 0 – 1023
Default value on standard viewer software: 512
Digital gain = gain value x 0.03125 – 6.0 (dB)
Example 1: When default value is 512,
Analog gain = 512 x 0.03125 – 6.0 =10(dB)
10.2.
Optional functions (please contact us for further details.)
・Analog gain:
Can be set to 3dB, 0dB, 6dB, 12dB or 18dB
・Black level correction
By default, black level correction is set automatically, and the Pedestal level is set to 32 at 10bit.
(When output is at 8bit, the Pedestal level is approximately 32 / 4 = 8.)
The target value of Pedestal level (32) can also be modified.
*AD conversion to 16 bit and then
output the upper 10 bit to digital gain
- 13 -