Alva GDH101 Manual - Página 16
Navegue en línea o descargue pdf Manual para Placa Alva GDH101. Alva GDH101 17 páginas.
También para Alva GDH101: Manual (18 páginas)
TROUBLE SHOOTING GUIDE
Stong gas odour •
•
•
Combustion is
•
abnormal
•
•
Model
Description
Gas
Ignition system
Jet Size
Rated pressure (kPa)
Gas consumption at Max
TO BE USED WITH A 2.8 kPa SANS 1237 APPROVED REGU-
LATOR ONLY, WITH A MINIMUM CAPACITY OF 1kg/hr
Any modification to the hob may cause injury
Any modification to the hob will invalidate the warranty
Gas leak from
•
hose
Hose is dam-
•
aged
Burner is not lit
•
Lack of gas
•
supply
Flame ports are
•
clogged
Burner is not
in its correct
•
position
SPECIFICATIONS
GDH100
60cm 4 Burner Gas Hob
LPG
Electronic ignition (PZT)
1 x D Battery
0.5mm x 1 - Auxiliary
0.62mm x 2 - Semi rapid
0.9mm x 1 - Wok
2.8kPa
73g/h - Auxiliary burner
127g/h - Semi rapid burner
240g/h - Wok burner
or property damage.
on this appliance.
Examine hose
using soap
water,and
replace hose .
Replace it
Re-ignite burner
Replace gas
cylinder
Clean flame
ports
Place burner
components
in the right
position
14
If you are still unable
to correct the problem
with the information
in this guide , then
you need to contact
your nearest dealer or
manufacturer.