Alvarado Supervisor 500 Manual de instrucciones de instalación - Página 15
Navegue en línea o descargue pdf Manual de instrucciones de instalación para Torniquetes Alvarado Supervisor 500. Alvarado Supervisor 500 19 páginas. Barrier-free optical counting turnstile
Testing Turnstile Functionality (cont.)
BLOCKED SENSOR
TEST
PROCEDURE
Using your hand or other object, block the
sensors for at least 15 seconds.
LINGERING
TEST
PROCEDURE
Walk into the lane, and remain in the lane for
at least 15 seconds.
Page 28
For Assistance: [email protected] +1 (909) 591-8431
SU500 Installation Instructions
TURNSTILE RESPONSE
•
After 15 seconds, the Blocked
Sensor alarm will sound. The alarm
will continue to sound until you the
obstruction is removed.
TURNSTILE RESPONSE
•
After 12 seconds, the Loitering alarm
sounds.
PUD1456R5-0
SU500 Installation Instructions
Testing Ethernet Communication (Optional)
NOTE
The following procedure is applicable to non-networked (standalone) turnstiles.
Required Items:
•
CAT5/6 Ethernet Cable
•
Laptop Computer Running Windows 7 or Windows 8
1.
Locate the Ethernet port on the main turnstile controller
[Figure 31].
2.
Connect the Ethernet cable to the Ethernet port.
3.
Connect the other end of the Ethernet cable to the laptop
computer.
Launch Command Prompt on the computer by
4.
typing CMD in the 'Search programs and files' field.
5.
Enter the following command: ping XXX.XXX.X.XXX,
where XXX.XXX.X.XXX is the IP address of the
turnstile [Figure 32].
NOTE
192.168.0.100 is the default IP address configured by Alvarado.
If the turnstile has been assigned a different network IP
address, ping that IP address instead. Contact your system
administrator for network information.
6.
A successful ping will result in the message shown in
[Figure 33]:
Figure 32
Ping Results
PUD1R5-0
For Assistance: [email protected] +1 (909) 591-8431
Figure 31
Main Turnstile Controller
Ethernet
Port
Page 29