AKO H 260/1 Datos técnicos

Navegue en línea o descargue pdf Datos técnicos para Calentador AKO H 260/1. AKO H 260/1 2 páginas.

AKO H 260/1 Datos técnicos
1. Warnings
Please read these instructions carefully. Keep these
instructions in a safe place and pass them on to possible
future owners.
Use device for room heating within enclosed rooms
-
only.
Repairs and corrective measures may only be carried
-
out by skilled electricians.
Disconnect the power supply in the event of fault or
-
when device is not used for an extended period of
time. Pull out the device plug or switch off the fuse.
Do not cover the heating device with any
-
objects; fire hazard!
The device carries the symbol shown on
the right which indicates that the heating
device must under no circumstances be covered with
any objects.
Caution! The outer surfaces of the device are hot
-
during operation.
Do not operate the heating device without supervision
-
when small children can get close to the device.
-
Observe the applicable provisions for setting up power
installations with nominal voltages of up to 1,000 V
when assembling and installing the devices.
Install the device in such a manner that the controls
-
cannot be touched by a person in the bathtub or under
the shower.
Do not operate the heating device in rooms where
-
highly inflammable substances are used (e.g.
solvents, etc.).
Do not lay the connecting cable across the hot device.
-
Caution! If the thermostat switches on the connected
-
unit automatically during your absence, there is a
potential danger of fire if, for example, the unit is
covered or if it is blocked by objects.
2. Technical Data
Connection voltage: 1/N/PE ~ 230V 50 Hz
Nominal output H 260/1, H 261/1: 2,000 W
Nominal output H 260/2: 1,000 W
Dimensions: (W x H x D) 290 x 410 x 135 mm
H 261/1: Clock timer 0 - 60 minutes
Degree of protection IPX4, protection class I.
3. Minimum Clearances and Installation
The heater may only be installed and operated in a vertical
position on vertical walls.
Do not place the heating device directly below wall sockets.
Install the device in such a manner that the controls cannot
be touched by a person in the bathtub or under the shower.
The plug must be accessible after installation.
H 260/1, H 260/2, H 261/1
The minimum clearances listed in the installation drawing
must be strictly observed.
100
100
300
Dimensions in mm
In addition, a minimum clearance of 350 mm between
inflammable objects and the front of the unit must be
maintained.
Especially highly inflammable objects such as textiles or
heat-sensitive plastics should be kept away from the hot air
flow.
The wall bracket is mounted to the wall with 2 screws. The
enclosed plastic bag contains screws and dowels.
Mounting Instruction:
1. Remove the wall bracket from the back of the unit.
2. Drill mounting holes for the wall bracket and insert the
dowels.
3.
Align the wall bracket and firmly screw it onto the wall.
4. Loosen the locking screws (III) by approx. 5 mm.
5. Hang the heating device onto the wall bracket using the
slots on the back of the unit (II).
6.
Retighten the locking screws to secure the unit against
coming off inadvertently.
Top
410
1
E L E K T R O G E R Ä T E
100
230
305
290
135