8. Technical information

Nominal output
Regulated output
Efficiency
Weight
Flue outlet
Dimensions (mm)
Average wood consumption (kg/h)
Max. allowed wood batch (kg/h)
The greatest height of the filling
Fuel supply interval for the rated
output
Fuel delivery method
Prescribed fuel
Door with spring return
Door design
Chimney draft (Pa)
Mass flow rate of dry flue gases
(g/s)
The concentration of CO in the flue
gases at O2 = 13%
The concentration of CO in the flue
gases at O2 = 13% (mg/Nm3)
The concentration of CO in the flue
gases at O2 = 0% (mg/MJ)
Dust at O2 = 13% (mg/Nm3)
Average flue gas temperature (°C)
7 kW
3.5 - 10 kW
85%
150 kg
150 mm
1003x589x
490
1.9
2.5
1/3 of firebox
1 hour
Manual
Wood
Yes
Left
12
4.9
0.089
1117
753
Approvals
EN 13240/2002+A2/2005
13
DIN plus
218
EN – Procedure for exchange of chamottes:
1. Pull out the ceiling fireclay plat – 1
2. Pull out the side fireclay plates - 2
3. Pull out the bottom fireclay plates - 4
4. Pull out the rear fireclay plates - 3
5. Use the reverse order for re-assembly
Note: Cracks in the chamotte do not have
any effect on the combustion and service
life of the stove. The chamottes should not
remain crumbled to the metal for prolonged
periods of time.
Warning: When stoking logs, make sure they
do not hit the chamottes hard to prevent
damage!
3