DOEPFER A-100 Series Manual del usuario - Página 11

Navegue en línea o descargue pdf Manual del usuario para Controlador DOEPFER A-100 Series. DOEPFER A-100 Series 12 páginas. Analog modular system, connecting the breakout module to the main module
También para DOEPFER A-100 Series: Manual de instrucciones (8 páginas), Manual (16 páginas), Manual de montaje y cableado (6 páginas), Manual (8 páginas), Manual (8 páginas), Manual (6 páginas), Conexión (8 páginas)

DOEPFER A-100 Series Manual del usuario
Check very carefully that it is connected so that the coloured marking on the
ribbon cable is at the bottom of the bus connector. The coloured marking
has to align with the "-12V" printing on the bus board next to the pin header. In
addition there is a line marked "RED WIRE" on the A-100SSB pc board.
Check also very carefully that it is pushed fully home, not at a slight angle
and not vertically or horizontally displaced .
Failure to check this may result in the module' s and/or supply's instant
destruction as soon as the power is turned back on!
When you' re installing extra modules, it may be necessary to take another
module or two out, to allow you easier access to the bus board.
Remove or install modules only during POWER OFF !
Additional information about the modular system A-100 is available on our website
www.doepfer.com. Important links are e.g.
www.doepfer.com
www.doepfer.com
www.doepfer.com
Products
A-100
Products
A-100
FAQ
A-100
....
Technical details
Mechanical details