MAINTENANCE:

AIR STORAGE TANK - To avoid the risk of moisture
in the air lines or tank failure, drain the tank after
each use or every four hours of operation. This will
DRAIN FITTING
prevent condensation build-up and corrosion inside
the tanks. To drain the tank, allow the compressor
to fully pressurize and then turn the power switch to
the off (O) position. Remove the power cord from
the receptacle on the end of the compressor case.
Locate the drain fitting on the underside of the
compressor Carefully and quickly turn open the
drain fitting. Return the unit to its normal position
and allow water to drain out with the escaping air.
AIR FILTER - A dirty air filter will not allow the air
compressor to operate at full efficiency. If a
decrease in the supply air is noticed, it may be
necessary to replace the filter element. The air filter
is located inside the case along the side of the
pressure switch. To replace the filter, disconnect the
hoses and unscrew the brass cylinder at its mid-
section. Remove filter disc and install a new one.
P/N 730041
AIR INTAKE FILTER
PRESSURE SWITCH
AIR FILTER
AIR STORAGE TANK