Setting Function List
Display
Setting Function (Default Value)
(1)
Counter ON/OFF Setting
(2)
Count
(3)
Count Timer
(4)
Work Reset Timer
(5)
Reverse Count Timer
(6)
System Setting
(7)
Over Time/Short Time
(8)
Accumulated Counter
ASG, Division of Jergens, Inc.
S. Waterloo Road | Cleveland, OH
15700
HIOS BLG-BC1 Series
Operational Manual
Symbol
| Phone: (
44110-3898
888) 486-6163
Setting Description
ON: When selected, the counter function is available.
OFF: When selected, it is used as a normal screwdriver. The display is also OFF.
The screw fastening count value is set. Setting Range: 1 to 99
This function is used to prevent the count for double tightening operations such as
check fastening or retightening. Set the operation time while the check fastening is
performed for the tightened screw. Setting Range : 0.00 to 0.99 seconds. Note: When
the screw tightening operation is performed during setting and the judgment result is
normal, the buzzer sounds once.
The buzzer sound time period after the work is completed is set. Setting Range: 0.0 to
3.9 seconds. Note: Set it based on the reverse count timer set value.
The time period until the reverse count is performed is set. Set the work reset timer
operation time based on the time period up to when the reverse count is performed.
Setting Range: 0.1 to 1.0 seconds. Note: It is available when the "Reverse Count
Enable" has been set in the system setting.
Each Buzzer or Reverse Count Enable/Disable is set up. The setting is performed with
a combination of the tens digit and single unit digit.
Tens Digit
0 : Buzzer Enable/Reverse Count Enable
1 : Buzzer Enable/Reverse Count Disable
2 : Buzzer Disable/Reverse Count Enable
3 : Buzzer Disable/Reverse Count Disable
Units Digit
2 : Torque Up Buzzer Disable
3 : Torque Up Buzzer Enable
This sets whether or not the Over Time/Short Time error is detected.
"0 : When selected, neither Over Time or
Short Time Error is detected."
1 : When selected, only the Short Time Error is detected.
2 : When selected, only the Over Time Error is detected.
3 : When selected, both Over Time and Short Time Error are detected.
The Total count of the screw fastening operations is displayed. For the total count, all the
fastening operations are counted regardless of whether the counter is ON/OFF.
Display:
Units Digit:
Tens Digit:
Units Digit: Numbered in multiples of 100,000 shots
Tens Digit: Numbered in millions of shots
| Fax: (
| Email: [email protected] | Web: www.asg-jergens.com
216) 481-4519