6.2 Rear Panel

1
2 3 4
5
LAN:
1
This slot is to connect with CAT5/6 cable from an IP router for on-
line fi rmware updating with a website designed by the device's
designer. Or may be a control terminal on-link from a designate IP
address.
RS-232:
2
This slot is to connect with D-Sub 9pin cable from the PC/NB device
for RS-232 control.
IR-In:
3
This slot is to connect with the IR extender included in the package
for IR signal receiving from the remote control of this device.
4
Service:
This slot is to connect with USB cable for manufacturers' fi rmware
update only.
DVI OUT A~H:
5
These slots are to connect with display or monitor with DVI cables
for output image display.
6
DVI IN 1~8:
These slots are to connect with input source equipment such
as Blu-ray player or Set-Up-Box with DVI cable or HDMI to DVI
converter cable for input signal sending.
7
DC24V:
This slot is to plug the power cord with adaptor included in the
package and then connect them with AC wall outlet for power
supply.
3
A
B
C
1
2
3
DVI OUT
D
E
F
DVI OUT
4
5
6
DVI IN
6
F
G
GND
V+
V+
3
4
1
2
GND
GND
7
8
DC 24V
7
3