Note: Before changing the default settings values of the device, ensure the maximum
ampere and voltage ratings applicable for your battery type (SMF,LEAD ACID etc) and
brand. Blind settings may cause severe damage to the batteries and charge controller.
Default values given are for lead acid

ENTERING SETUP MODE:

bank. To enter Setup Mode, connect the settings key to the 9-PIN D-Connector. Press and
hold the ENTER button on the key and switch on the MPPT ON-OFF switch on the device
till the charger enters the SETUP MODE on display. All the indicators and fan start to
function. Press the ENTER button to scroll through the setup menu as shown below. Use
the PLUS and MINUS buttons to increase or decrease the default values.
MENU
1.CAL-AMP
(AMPS
Calibration
CALIBRATION)
2.CAL-VOL
Calibration
(VOLT
CALIBRATION)
3.BVH-CUT
(BATTERY
Settings
CHARGING HIGH
CUT OFF VOLT)
4.MAX-AMP
(CHARGING
Settings
AMPS)
5.GRD-SOL
Settings
(GRID TO SOLAR
CHANGE OVER)
6.SOL-GRD
Settings
(SOLAR TO GRID
CHANGE OVER)
7.BLK-LED
Settings
(LOW BATTERY
WARNING)
Note: Values will be displayed as multiples of 10 (e.g. 14.5V will be displayed as 145)
SETUPMODE
Switch OFF the device and connect to the desired battery
TYPE
Increase or decrease this value to match the
ampere shown on the display to the reading
on your True RMS DC clamp meter. (
brand is recommended)
Measure the terminal voltage of the battery
bank using a DC volt meter and equalise the
reading shown in the display of the charger
to your volt meter reading
Set the battery charging
high voltage cutoff volt
Set the maximum charging current cutoff
(Max charging current value is
recommended as 20% of the Ah of a single
12V C10 Battery connected in series. e.g. for
a 150 Ah C10 Lead Acid battery, 30A is the
recommended charging current)
Set the battery voltage you prefer to shift
automatically from grid power to inverter
(solar power)
Set the battery voltage you prefer to shift
automatically from inverter to grid power
Set the low battery level of warning
indication LED to blink
batteries.
DESCRIPTION
11
RANGE
MIN
DEFAULT
50
115
FLUKE
-
13V
14.5V
3A
40A
12V
14.0V
9V
11.0V
LB
11.7V
MAX
220
--
-
16V
40A
16V
16V
16V