ASHE STL-94 Manual de instrucciones - Página 12
Navegue en línea o descargue pdf Manual de instrucciones para Equipos de grabación ASHE STL-94. ASHE STL-94 17 páginas. Stream selector
Use SHIFT key to shift cursor to desire digit and INC key to change the desire digit from 0 to 9. The High
Alarm can be set throughout the range.
Press MODE key to proceed further. After pressing MODE key, the microcontroller will save High Alarm
setting for stream no. 01 and move to next parameter.
In the same sequential process, the following parameters for each Stream can be set :
Low Alarm for Streams 2. 3. 4.
High Alarm for Streams 2, 3, 4.
Press MODE key to proceed further. After pressing MODE key, the microcontroller will save High Alarm
setting for stream no. 04 and exit from STREAM ALARMS MODE.
This completes the Stream Alarm settings.
After pressing MODE key, the LCD Display will return to the normal PROCESS SCREEN.
RETRANSMISSION (4-20 mA DC) OUTPUT CALIBRATION MODE
The ASHE Stream Selector Model STL-94 provides individual 4 to 20 mA retransmission output for each
stream. All retransmission outputs are factory calibrated and do not require recalibration at the
customer's side. So do not enter into Retransmission Calibration Mode unless the instrument requires
recalibration.
Before entering into Input Calibration Mode, ensure that a reliable 4 to 20 mA source is connected to
the instrument at the Input terminals with correct polarity.
Feed a DC current less than 4 mA the source to the instrument. The process value on the LCD Display
will show "Low".
Enter the number 05 into Select Menu by using INC key in the PARAMETER SETTING MODE SCREEN.
Press the MODE key to enter into Retransmission Output Calibration Mode.
The LCD Display shows :
Press SHIFT key to move the cursor to the last digit.
Enter the Password 0004 by using INC key and press MODE key.
After pressing MODE key the LCD Display will show :
Password
0000
O/P zero adjust 01
34
ASHE CONTROLS PRIVATE LIMITED.
S
S
STL-94
TREAM
ELECTOR
Operation Manual