Ashland AC-15 Funcionamiento, rendimiento, especificaciones y manual de piezas - Página 2
Navegue en línea o descargue pdf Funcionamiento, rendimiento, especificaciones y manual de piezas para Bomba de agua Ashland AC-15. Ashland AC-15 16 páginas. Condensate utility pump
PRE-INSTALLATION
BEFORE USE
Examine the pump and all parts to ensure no parts are dam-
aged. If any part of the pump appears to be damaged, do not
use this pump and contact 1 877 326-3561 for assistance.
INTENDED USE
Your condensate pump is designed as an automatic conden-
sate removal pump for water dripping off an air conditioner
evaporative coil. The pump is controlled by a float/switch mecha-
nism which turns the pump on when automatically 2-1/4" of water
collects in the tank and automatically switches off when the tank
drains to approximately 1-1/4".
SPECIFICATIONS & PERFORMANCE
Model
HP
AC-15
1/12
INSTALLATION
MOUNTING THE PUMP
Do not install this pump in a
manner that will subject it to
splashing or spraying.
The tank has two slots provided to mount the unit. The slots
are located on the ends of the tank. The unit should be mount-
ed either on the side of the air conditioner unit or a nearby
wall. The pump must be level and the inlet must be below the
coil drain. Conduit fittings are not compatible with the
plastic pump housing.
Check Valve
Condensate Utility Pump
Model: AC-15
Installation
Volt
Amps
115
1.5
Mounting Slots
BEFORE INSTALLING THE PUMP
Before installing the pump, allow the air conditioner to cycle
several times, collecting condensate in a separate container
to help flush any residual oils that may have remained in the
system.
MATERIALS REQUIRED (NOT INCLUDED)
Before using this pump, ensure you have the following items:
Safety Glasses, Philips Screwdriver, Level, At least two screws
(for wall or air handler mount only), Wall Anchors (for wall only),
1/2" Hose Clamp.
GPH of Water @ Total Feet of Lift
0 ft.
5 ft.
10 ft.
100
83
The Safety Switch NC and COM leads can be connected
in series with a low voltage thermostat circuit. This will
protect against overflow by shutting down heating/air-
conditioning system if water level in pump tank rises
above normal level. An optional alarm can be connected
to the NO termenal.
Thermostat
Terminal
Connection
in Furnace
2
15 ft.
Max. Lift
67
42
18 ft.
Optional Alarm
Hook Up
Typical
Thermostat
NC
NO
COM