Cloud CA4250 Manual de instalación y uso - Página 8

Navegue en línea o descargue pdf Manual de instalación y uso para Amplificador Cloud CA4250. Cloud CA4250 19 páginas.
También para Cloud CA4250: Boletín técnico (13 páginas)

Cloud CA4250 Manual de instalación y uso
C l e a r l y b e t t e r s o u n d

CA Series amplifiers - main features

Output stage can drive 70 V/100 V-line systems
directly (transformerless), or low impedance
loudspeakers (≥4 ohms)
Output mode selectable per-channel
Balanced line level inputs
Per-channel output level controls
Per-channel rear panel input switches for input routing,
high or low impedance operation, 70 V/100 V-line
selection and high-pass filter
Automatic Power Down: <2.5 W power consumption
with all channels quiescent
Remote Power control input
Global disable of APD function
Variable speed forced-air cooling
Thermal protection, overcurrent limiting and DC offset
protection
Switch-on delay for speaker protection during power-up
Universal PSU – operates from 100 to 240 VAC

Block Diagram

Block Diagram
OPTIONAL AUXILIARY
INPUT CARD
8
CA Series Installation & User Guide v1.0
Available Options:
CDI-CA2, CDI-CA4, CDI-CA8 Dante® input cards
(providing 2, 4 and 8 Dante input channels respectively)

What's in the Box

Please check the shipping carton for damage before opening.
If there is damage, please contact your Cloud agent and the
shippers.
The packing carton should contain the following items:
Cloud CA Series amplifier
Set of mating plug-in screw-terminal connectors
Mains cable(s)
INPUT
ROUTING
AMP
LIMITER
SPEAKER LOAD
CONFIGURATION
4Ω / 70V
HI-Z
PROTECT
1
1
8Ω / 100V
ON
LOW-Z
ON