Ashly Protea NE8250.10 Manual de instrucciones - Página 11

Navegue en línea o descargue pdf Manual de instrucciones para Hardware informático Ashly Protea NE8250.10. Ashly Protea NE8250.10 16 páginas. Network enabled multi-channel power amplifiers
También para Ashly Protea NE8250.10: Manual de instrucciones (16 páginas), Manual de instrucciones (16 páginas), Especificaciones (2 páginas), Hoja de especificaciones (2 páginas), Manual de instrucciones (16 páginas), Manual de instrucciones (20 páginas)

Ashly Protea NE8250.10 Manual de instrucciones
Operating Manual - NE Multi Channel Power Amplifier
neWR-5 Networked Programmable Remote Control - The neWR-5 remote control is a networked version of the
WR-5, using Ethernet instead of the Data Port to communicate with the amplifier. Connecting and powering the neWR-5 is
done using Cat-5 Ethernet cable and a Class 1 IEEE 802.3af Power over Ethernet (PoE) switch, hub, or in-line PoE injector.
If PoE is unavailable, the Ashly RPS-18 (sold separately) is a 15-48VDC power supply capable of at least 2 watts per neWR-5
and can be hard wired to the back of the neWR-5. PoE current draw is 38mA @48VDC and 80mA@15VDC. A decora cover
plate (not included) can be purchased at hardware stores to cover the neWR-5 electrical box and satisfy the aesthetic needs of
the installation.
The neWR-5 appears in the Protea
cific amplifier under control. The neWR-5 has six programmable function buttons which can light up green, red, or amber to
display status. Further information on LED status is found in the neWR-5 owner's manual. To the right of the function buttons
is a pocket in the mylar overlay for a printed function label to be inserted. The two other buttons are used to adjust function
parameters such as gain or preset number, and are indicated by the LED display. neWR-5 functions are limited to preset recall
and mute unless there is DSP installed in the amplifier. Note: To use the neWR-5 as a remote level control, a (ne)WR-5 Remote
Gain tool must be placed in one of the DSP processing blocks of the channels(s).
There is a hard-wired Lock-Out feature on the neWR-5, where the closing of a switch wired to the lockout Euroblock
renders all buttons inactive.
FR-8 and FR-16 Networked Fader Controller - The FR-8 (shown at
right) and FR-16 are Ethernet based remote fader control units, with the ability
to assign each fader control of one or more input or output DSP gain stages or
level control for a DSP matrix mixer point. The button LED for each fader is
normally used to indicate assignable signal level/clip or mute status, but can
alternately indicate A/B source selection for that fader. The FR remotes can
be wall mounted to electrical box, panel mounted, or freestanding, and have a
back panel contact closure for full front panel lockout. See further details in
the FR-8/16 owner's manual on the Ashly website.
software device menu tree and must be assigned within it's device window to a spe-
ne
11