Dolphin Dolphin Blue BCL632F Manual de instalación y mantenimiento - Página 15

Navegue en línea o descargue pdf Manual de instalación y mantenimiento para Dispensador Dolphin Dolphin Blue BCL632F. Dolphin Dolphin Blue BCL632F 17 páginas. Panel mounted foam soap dispenser
También para Dolphin Dolphin Blue BCL632F: Manual de instalación y mantenimiento (19 páginas)

Dolphin Dolphin Blue BCL632F Manual de instalación y mantenimiento
TROUBLE SHOOTING
PROBLEM
INDICATOR
Foam does not
stop dispensing
Foam is too
diluted
Foam is too
dense
Blue light flashes
Soap dispenser
(once) and the
pump does not
foam compressor
work
operates.
Foam
Blue light flashes
compressor
(once) and the
does not work
motor operates.
CAUSE
The connectors between the pump
and the electronic unit are not
connected properly.
Air ratio is too low.
Air ratio is too high.
The connectors between the soap
pump and the compressor are not
connected properly.
The connectors between the
compressor and the electronic unit
are not connected properly.
SOLUTION
Connect the connectors
properly so that the white
o-ring is not visible.
Increase air ratio using the
remote control.
Refer to page 8
Decrease air ratio using the
remote control.
Refer to page 8
Connect the connectors
properly so that the white
o-ring is not visible.
Connect the connectors
properly so that the white
o-ring is not visible.
BC632F
|
Dolphin Blue
|
15