ASI EZFILL10-0390-6-1A-41 Manual de instalación y mantenimiento - Página 8
Navegue en línea o descargue pdf Manual de instalación y mantenimiento para Dispensador ASI EZFILL10-0390-6-1A-41. ASI EZFILL10-0390-6-1A-41 16 páginas. Soap dispenser
INSTALLATION
Cut the 5/16" dia (Ø8) soap supply clear
tube coming from the EZFILL™ Pump-
5
Motor to the right length as required by
the installation.
Make sure the end of the tubes are about 1" (25)
longer than required to reach the tank bottom.
Connect the EZFill™ Pump-Motor clear
5/16" dia. (Ø8) soap supply tube to any
6
available locking bushing in the soap tank
cap (see 0390 OM & IG).
NOTE: The Multifeed Kit enables soap distribution for up to six (6) soap
dispensers simultaneously. When installing less than a full complement
of soap dispensers, make sure to insert and clamp the 5/16" dia x 1" long
(Ø8x25) plugs into the remaining empty holes provided.
Remove the protective sticker
7
covering the sensor. Keep away
from the sensor range.
Connect the Com Cable motor connector to the mating plug from
8
dispenser (If not already connected in Step 3 above). Please note
that since the connector is water proof, some friction will apply.
O-RING VISIBLE –
IMPROPERLY CONNECTED
Important: the 4 contacts connector should be inserted fully so that the
white O-ring is not visible and a clicking sound is heard.
NOTICE: If the 4 contacts connectors are not connected properly, the motor
will run continuously.
7
1408201234 Rev J
CONNECTING THE POWER SOURCE
Fill
Hose
ONLY THE GROOVES ARE VISIBLE -
CONNECTED PROPERLY
Soap Supply
Tube
05 August 2015