Ega Master 66266 Manual de instrucciones - Página 8
Navegue en línea o descargue pdf Manual de instrucciones para Instrumentos de medida Ega Master 66266. Ega Master 66266 18 páginas. Outer digital micrometer
- Incremental capacity measurement system
- Carbide measurement surface
- Built in wireless transmission(optional)
- Measuring force:5-10N
- Measuring power consumption: <60μA
- Working temperature: 0-40ºC
- Storage and transportation: -20-60ºC
- Environmental humidity:<80%
- 3V CR2032 lithium battery, battery life>1 year.
Range of measurement
0-25mm/0-1"
25-50mm/1-2"
50-75mm/2-3"
75-100mm/3-4"
100-125mm/4-5"
125-150mm/5-6"
Caution
Although you own the high-quality product, like any other electronic product, appropriate
attention is necessary.
1. Please clean the measuring surface before using the micrometer to reduce the measurement
error.
2. To avoid product contacted with liquid, exposure in sunshine, do not wash the product, do not
disassemble or collide the product..
3. Do not place the micrometer in an overheated or supercooled environment or in a strong
magnetic or high-pressure environment.
4. About the battery: forbid to charge or burn, the old battery must be disposed according to the
local laws and regulations
5. In order to ensure the good condition of measuring tool for long time, clean the oil
contamination and liquid on the measuring tool with the soft cloth after using.
6. If you do not use for a long time, please take out the battery.
Problem
Measuring data incorrect
No display on LCD
1. Flickering display
2. Display sporadic
3. Display remains dead
1. Display is blurry
2. Output data is incorrect
8
4. PRODUCT CHARACTERISTICS
Accuracy of indication: 0.003mm/0.00015"
Accuracy of indication: 0.003mm/0.00015"
Accuracy of indication: 0.004mm/0.00015"
Accuracy of indication: 0.004mm/0.00015"
Accuracy of indication: 0.005mm/0.0002"
Accuracy of indication: 0.005mm/0.0002"
6. FAILURE REMOVAL
Cause
1. Dirty measuring faces
2. Zero is incorrect
1. Battery position is incorrect
2. Battery is dead
1. Weak battery
2. Weak battery
3. Battery position is incorrect
Weak battery
Solution
1. Clean measuring faces
2. Inspect and reset zero
1. Reset battery
2. Replace with new battery
1. Replace battery
2. Replace battery
3. Reset battery
Replace with battery