Ambic Equipment Ltd – EasiDoser™ Operating Notes

Electrical Connections

WARNING!
DISCONNECT UNIT COMPLETELY
FROM MAINS POWER BEFORE OPENING
LID.
Unscrew the 2 screws in the corners of the
enclosure. Hinge lid open to reveal the PCB
inside lid.
Terminal blocks may be pulled off from the
PCB to allow easy connection of wires into
Screw Terminals.
Positions of wires are noted LEFT >> RIGHT
(see PCB Layout diagram below right)
MAINS
= 220-240V AC
= LIVE – Brown wire
L
= EARTH – Green/Yellow wire
E
= NEUTRAL – Blue wire
N
= Pump 1 – Pink wire +
P1
Grey wire -
= Pump 2 – Pink wire +
P2
Grey wire -
= Pump 3 – Pink wire +
P3
Grey wire -
Opto 4
= Signal wire Pump 1
12-230V AC via Opto Isolator
12-24V DC via Opto Isolator
Close contact direct input
Opto 5
= Signal wire Pump 2
12-230V AC via Opto Isolator
12-24V DC via Opto Isolator
Close contact direct input
Opto 3
= Signal wire Pump 3
12-230V AC via Opto Isolator
12-24V DC via Opto Isolator
Close contact direct input
FS1 & 2
= Float Switch 1 & 2
– Brown wire
– White wire
Figure 3 – EasiDoser
PUMP 1
MENU "CONFIRM" BUTTON
PUMP 2 ON 3 PUMP SYSTEM
Figure 4 – EasiDoser
Opto 4
Opto 5
FS1
Opto 3
FS2
-5-
Switch Operations
ON/OFF SWITCH
PUSH > ON
PUSH > OFF
PUMP 2 ON 2 PUMP SYSTEM
PUMP 3 ON 3 PUMP SYSTEM
MENU
NAVIGATE
BUTTON
Electrical Connections
P2
L E N
Mains
P3 if fitted
P1
ADE7500 v1.3 (16/03/18)