Ambic Equipment Ltd - OptiFlow™ Operating Instructions
6.
TROUBLE SHOOTING
FAULT
1. Chemical does NOT fill
dip cup when trigger
pressed (or fills very
slowly)
2. Applicator cup
continues to fill after
trigger released.
3. Chemical running out
of Power Unit.
4. Chemical leaks into
Vacuum Line.
CAUSE
a) Vacuum pump not switched
on.
b) Vacuum line not airtight.
c) Constricted Vacuum Supply
Pipe (G).
d) Chemical Container (D) is
empty.
e) Intake Filter (K) is blocked.
f) Pressure Line (N) is blocked.
g) Inlet to cup assembly (V) is
restricted or block.
h) Pump AOFL/2004-V is faulty.
i) Directional Valve ATS/425 is
faulty.
j) Air in Pressure Line (N).
Debris in applicator valve, or part
is damaged.
a) Loose Connector Nut.
b) Pump Head Manifold.
c) Faulty pump.
Pump faulty.
-9-
REMEDY
a) Switch on vacuum pump.
b) Check that vacuum is
reaching the power unit by
pulling supply pipe out and
testing with finger.
Check vacuum pipe adaptor
is correctly installed.
c) Check for kinks and
overtightened cable ties.
d) Fill container.
e) Clean filter.
f) Clear blockage, check for
constriction or kinks in the
tubing, or for tight cable ties.
g) Check inlet underneath the
top rim and clean using
warm water if chemical
residues are apparent (see
Fig. 5)
h) Check pump and repair or
replace.
i) Check valve and repair or
replace.
j) Vent as described under "2.
Initial start-up".
Ensure that an Intake Filter (K)
is fitted, and that the chemical &
container are free of debris.
a) Locate leak and tighten the
nut.
b) Check the screws are tight.
c) Check the pump and repair
or replace.
Immediately turn off the vacuum
at the tap. Repair or replace the
faulty parts.