There are dashes (--) on the display
console.
Temperature sensor reads too high in the
day time.
Indoor and Outdoor Temperature do not
agree
Indoor and Outdoor Humidity do not
agree
Console outdoor humidity and remote
humidity do not agree.
Relative pressure does not agree with
official reporting station
Version 2.1
©Copyright 2015,
will turn on. Wait several minutes for the remote
sensor to report in, or the search icon to turn off.
If the synchronization fails, reset the console by
removing one battery from the display console,
wait 10 seconds, and reinsert the battery.
Do not press any buttons while in the search
mode.
2. Check the remote sensor is powered up and
displaying the temperature and humidity on the
LCD display.
3. Install a fresh set of batteries in the remote
thermo-hygrometer. For cold weather
environments, install lithium batteries.
4. The maximum line of sight communication
range is 300'. Move the sensor assembly closer
to the display console.
5. If the sensor assembly is too close (less than
5-10'), move the sensor assembly away from the
display console.
6. Make sure the remote sensors are not
transmitting through solid metal (acts as an RF
shield), or earth barrier (down a hill).
7. Move the display console around electrical noise
generating devices, such as computers, TVs and
other wireless transmitters or receivers.
8. Move the remote sensor to a higher location.
Move the remote sensor to a closer location.
9. Radio Frequency (RF) Sensors cannot transmit
through metal barriers (example, aluminum
siding) or multiple, thick walls.
Make sure the thermo-hygrometer is mounted in a
shaded area on the north facing wall.
1. Allow up to one hour for the sensors to stabilize
due to signal filtering. The indoor and outdoor
temperature sensors should agree within 4 °F
(the sensor accuracy is ± 2 °F).
2. Perform a temperature calibration (reference
Section 4.2.5)
1. Allow up to one hour for the sensors to stabilize
due to signal filtering. The indoor and outdoor
humidity sensors should agree within 10 % (the
sensor accuracy is ± 5 %)
2. Perform a humidity calibration (reference
Section 4.2.4)
The console displays the calibrated humidity. The remote
displays the measured humidity only. Refer to 4.2.4 to
set and reset the humidity calibration.
1. You may be viewing the relative pressure, not
the absolute pressure.
2. Make sure you properly calibrate the barometer
Page 18