Ambirad ARO40 Manual de instalación y funcionamiento - Página 3
Navegue en línea o descargue pdf Manual de instalación y funcionamiento para Calentador Ambirad ARO40. Ambirad ARO40 16 páginas. Oil fired tube heater
1 Commissioning, service and
warranty
Commissioning
After installation in accordance with these
instructions please contact Ambi-Rad
Service on 01384 489700 to arrange
commissioning of the product.
Note Failure to observe the above will
invalidate the warranty.
Service
To ensure continued and safe operation it
is recommended that the heater is serviced
every 6 months.
The manufacturer, whose address is
provided at the back of these
instructions, offers a maintenance
service. Details available on request.
Warranty
All parts and labour are covered for a
period of 12 months from the date of
commissioning. Any consumable parts
such as the burner nozzle used on routine
service are excluded from the warranty.
Please contact Ambi-Rad Service on
01384 489700 for further details.
2 Health & safety
Sole liability rests with the installer to
ensure that all site safety procedures are
adhered to during installation.
Sole liability rests with the installer to
ensure that protective safety wear such as
hand, eye, ear and head protection is used
during installation of the product.
Direct contact with oils or insulation
without the use of safety protection must
be avoided.
Do not rest anything, especially ladders
against the heater.
All installations must be in accordance
with the regulations in force in the
country of use.
Installers must be able to demonstrate
competence and be suitably qualified in
accordance with the regulations in force in
the country of use.
These instructions must be given to the
user on completion of the installation.
3 Electrical installation
Ensure the burner has a permanent live
supply in addition to the switch live
supply.
This appliance must be earthed.
Electrical supply must be via a fused
double pole isolator having a contact
separation of >3mm in all poles. The
installation shall conform to the
regulation in force in the country of use.
Switching and control is recommended on
the live conductor.
Supply 230V 50Hz single phase.
Current rating 0.7 amp max (inductive).
Fuse rating 5 amp per heater.
The plug supplied with the burner must be
wired as shown in the wiring diagram.
(See Fig 1 page 2).
For economic control of the heater(s) the
installation of a black bulb thermostat is
recommended and available from the
manufacturer.
Remote reset of control box is possible via
a momentary switch that is available from
the manufacturer.
1