Important information
Before installation and/or use of this
appliance please read these instructions
carefully to ensure that all requirements
are fully understood.
This appliance must be installed by a
registered engineer, or approved by
building control, failure to do so may
endanger life and property.
All the below instructions should work in
conjunction with building regulations
document J, if there is a variation the
most stringent requirement should be
adhered to.
Asbestos
C
This appliance contains no asbestos, if
M
there is the possibility of disturbing any
asbestos in the installation of this
Y
appliance then specialist advice must
CM
be sought and appropriate precautions
taken.
MY
CY
Location of the unit
CMY
The appliance must stand on a non-
K
combustible constructional hearth
which is at least 125mm thick with the
minimum dimensions as shown in the
opposite diagram (please see Building
regs. Document J for further
information).
If the appliance is to be fitted in a raised
application, due consideration should
be given to extending the depth of the
superimposed hearth to safely contain
any falling embers or logs.
The hearth and building construction
must be of a suitable material to comply
with current building and local authority
regulations. The fabrication of the
construction must have a suitable load
bearing capacity for the appliance and
hearth.
Installation Instructions
Metal Parts
This appliance may contain sharp metal
edges, take care when installing or
servicing this appliance to avoid
personal injury. Please use appropriate
personal protective equipment at all
times.
Each installation is unique to the
property, the information contained in
this manual may not give exact
installation requirements for your
installation.
The installation must comply with
Building Regulations, European
Standards and Local authority bylaws.
Fire Cement
Some types of fire cement are caustic
and should not be allowed to come into
contact with the skin. In case of contact
wash immediately with plenty of water.
If in any doubt, please consult a
competent person for advice before
proceeding.
150mm
Superimposed
Hearth
5
08/04/2019
16:33:23
500mm
150mm
225mm
Constructional
Hearth
125mm
888mm