AMC MOUSE 01/P Installation - Page 2

Parcourez en ligne ou téléchargez le pdf Installation pour {nom_de_la_catégorie} AMC MOUSE 01/P. AMC MOUSE 01/P 4 pages. Pet immune dual technology intrusion detector - duo-mask

ENGLISH
1. INTRODUCTION
pet immune 10kg
MOUSE 01 is a
MW detector. Owing to its special algorithm it is able to reach a coverage of 14 m and an angle of 90° , ensuring an
outstanding immunity to false alarms.
The detector can work with three different configurations:
➣AND: alarm is triggered only when detection is from both technology (maximum false alarm immunity)
➣OR with DUO-MASK protection: as soon as one technology detects, the alarm is triggered (for maximum sensi-
tivity)
➣DUO-MASK*: OR-type operation with notification of total inhibition of one of the two technologies (after mask-
ing or tampering, etc.).
note: the pet imunity function requires AND mandatory configuration
2. INSTALLATION
- By using a thin screwdriver, push the round tooth on the bottom and open the housing
- Remove the PCB from the base
- Use a screwdriver to pierce the knockouts on the side of the base where you wish to attach the detector to the wall
or use the optional swivel bracket
- Route the wires via the rear channel into the base and let them pass through the hole on the top of the housing
- Wire up the terminals following the connections shown in the figure
If you want to use the Back Tamper protection practice a hole of diameter bigger than the rawlplug you will use on the
back of the detector's cover in correspondence of the central knok-out (Please refer to the provided drill scheme).
Insert the rawlplug into the wall leaving the screw a little outside to ensure the back switch's contact closure and remo-
ve the jumper DISABLE TAMPER.
REMARK: the advised height from the floor is 2 m
Verify that all DIPswitches are OFF and disconnect terminal B/S.
Supply the detector and wait until the LED stops to flash.
Turn the trimmer to adjust the MW range, so as to let the MW detect the movements at the distance you need (lighting
of the red or green LED):
"+" ⇨ larger range "-" ⇨ smaller range
Close the detector and check the range in AND configuration (lighting of the red LED).
Open again the detector and continue with the following adjustements.
N.B. : To avoid false alarms, it is advised to start the regulation from the minimum position ( - ) and to increase
the range not more than necessary.
WARNING: By installing the detector at the corner or flag and disabling the Back-tamper device the product
will be downgraded to the I° Performance Level (CEI 79-2).
3. CONNECTIONS AND ADJUSTMENTS
MICROWAVE INHIBITION (dip 1 ON): If this function is active, the MW emission is automatically blocked when the
control unit is disarmed (B/S is applied + 12 Vdc) Note: stopping the MW detector disable the anti-mask device.
LED BLOCK: The LED is disabled when +12 Vdc voltage is applied to terminal B/S. Apply this voltage when the con-
trol unit is disarmed . B/S is therefore used to notify the detector the control unit status. Note: activation of B/S does
not influence the alarm contact, which is in any case enabled.
ALARM MEMORY: (dip 2 ON) The alarm memory is activated when the control unit is disarmed and can be distin-
guished by the slow flash of the LED (1 Hz) with the following mode:
RED: alarm from both technologies (MW and PIR, in AND); GREEN: MW alarm (only in OR configuration); ORANGE:
PIR alarm (only in OR configuration). Memory reset is carried out by arming the system.
OR CONFIGURATION - DUO-MASK (dip3 ON): Detector Mouse01 implements a device, which can detect a MW
masking attempt. For the time of this tampering, the NC ACC contact is opened and at the same time the LED flashes
quickly with a red colour. DUO-MASK: this is a special feature that enables to detect masking attempts of the PIR sec-
tion. To activate DUO-MASK configuration it is necessary to set dip 3 to ON .
1. General View
Led WALK TEST
Lente / Lens
Premere qui per aprire
Press here to open
www.amcelettronica.com
digital dual technology detector. It combines a dual element PIR and a 10.5 GHz-
Mouse 01 Dual Technology - Rev. 1.3
2
2. Inside View
Sfondabili per fissaggio
Mounting knockouts
Fissaggio circuito
Clip for electronic board
installation instructions