TROUBLESHOOTING

Do not repair or disassemble the unit by yourself, unauthorized repair
attempts will invalidate the warranty and may cause bodily harm.
Problem
Reason
No power supply.
Water-full indicator illuminated.
The unit
does not
Timer function is active.
work
Room temperature too low or too high.
In direct sunlight.
Windows or doors open.
Large amount of people or a
The unit
heat source in the room.
does not
seem to
Filter is very dirty.
perform.
Air inlet or air outlet is blocked
Room temperature is lower than the
desired temperature set.
The unit is
The unit is not on a flat surface.
loud
Compressor
does not
Overheating protection is active.
work
Operating distance is too far.
Remote
Control panel has not received
control
the signal from remote control.
doesn't work
The batteries are flat.
E1 on LED
Room temperature sensor is abnormal.
E2 on LED
Coil temperature sensor is abnormal.
Water tank is full inside the machine
Anti-freezing protection.
OTHERS
No refrigerant or there is very little
refrigerant.
High pressure protection.
If the above solutions do not resolve the problem please contact the retailer or
manufacturer.
Solution
Plug in and turn on the unit.
Drain the internal water tank.
Cancel the timer function.
Use only in ambient temperatures between 7-
40℃.
Draw the curtains, UV affects use air conditioner.
Close windows and turn on another air
conditioner.
Clean or change the air filter
Clear out debris.
Change the desired temperature.
Put the unit on flat surface. Place a piece of
carpet under the unit to prevent vibrations.
Check the vent pipe is not restricted.
Restart the unit after 10 minutes when
compressor has cooled.
Move remote control closer to the unit and
make sure it aims at the air-outlet grille.
Replace the batteries
Temperature not within 5-40℃ operating range.
If
the
temperature within operating range refer to
the retailer or manufacturer.
Refer to the retailer or manufacturer.
Drain water from drain port at bottom rear of
the unit.
Defrosting the coils within the unit. Normal
operation will resume automatically. No user input
is required.
Refer to the retailer or manufacturer.
After inside gas pressure comes down, it will
function normally. No user input needed.
10