Flofab LBV 315 Manuel d'utilisation, d'entretien et d'installation - Page 3

Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation, d'entretien et d'installation pour {nom_de_la_catégorie} Flofab LBV 315. Flofab LBV 315 14 pages. Submersible pumps series lbv

SINCE 1981

1. PRIOR TO OPERATION

1.1.
Be sure to provide an adequate grounding and install with leakage breaker to prevent the users
from serious electric shock injury.
1.2.
Make sure the voltage of the power supply are identical to the indications of the nameplate
(label) on the pump. Do not plug into other voltage and phase than indicated on the nameplate.
1.3.
Do not have a dry-run in the air, it will damage the pump.
1.4.
Do not use the electrical cable to carry, lift or lower the pump. Please carry by the pump handle.
Extension of power cable:
1.5.
When the power cable has to be extended, select the proper cable size within the allowable
extension. If cable is extended too far, a drop in voltage may occur, which will stop the running
of the motor and damage the pump.
DO NOT USE THE PUMP IN PONDS, SWIMMING POOLS, BATH TUBS, OR ANY OTHER AREA
WHERE THERE ARE PEOPLE; SERIOUS ACCIDENTS CAN OCCUR.

2. CARE UNdER OPERATION

2.1.
When the pump stops suddenly (by the motor protection device):
The motor protection device is built-in and shuts off the circuit automatically to
prevent the motor from burning-out when the motor is overloaded due to clogging by
foreign particles or when plugged-in to wrong power source (Voltage, Frequency, etc.).
Should the pump stop suddenly, please check piping, pump itself, connection of electrical cable
to power source, etc. The motor protector always automatically trips-off in a few seconds if there is any
abnormality. Please resume the operation after clearing the trouble and leave the pump as it is.
2.2
Please consult your local dealer or company from which the pump was purchased if you are
unable to solve the problem. Unauthorized personal is prohibited from disassembling or
assembling the pump as it will probably result in inferiority in performance or damage to motor.

3. CARE AFTER OPERATION

YOU DO NOT NEED TO TAKE ANY SPECIAL CARE ON THE PUMP AFTER OPERATION, HOWEVER, YOU MUST
BE WARN OF THE FOLLOWINGS:
3.1.
If a freezing temperature is predicted, lift up the pump from water and re-install it in dry condition.
3.2.
If pump is left in the water for a long period of time without running, rust and other possible
floating particals will accumulate in the pump, which will inevitably shorten the life of the pump.
In this case, let the pump run in clean water and remove floating particals from inside the pump.
Re-install it once dried.

4. APPLICATIONS

THE MOST EFFICENT, VERSATILE AND COST-EFFECTIVE PRODUCTS YOU'LL EVER USE!
-
Draining from buildings and sanitary facilities.
-
Water treatment process in sewage treatment yards.
-
Sewage waste containing slender material and all wastewater removal.
-
Draining other sewage water.
I.O.M - SUBMERSIBLES - LBV SERIES