TROUBLESHOOTING CHART

Symptom
Pump will not prime or retain
prime after operating
Pump runs but no fluid
Motor runs too hot
Flow rate is low
Pump leaks
Pump will not run
CONVERSION TABLE
TO CONVERT
Gallons, U.S.
Liters
Pounds/Sq. Inch
Bar
Fahrenheit
Celsius
WARRANTY
FLOJET warrants this product to be free of defects in material
and/or workmanship for a period of one year after purchase by the
customer from FLOJET. During this one year warranty period,
FLOJET will at its option, at no charge to the customer, repair or
replace this product if found defective in material or workmanship,
with a new or reconditioned product, but not to include costs of
removal or installation.
This is only an overview of our limited warranty. If you would like a
copy of our warranty, please call or write FLOJET.
www.flojet.com
U.S.A.
UNITED KINGDOM
Flojet
Flojet
17942 Cowan Avenue
Bingley Road, Hoddesdon
Irvine, CA 92614
Hertfordshire EN11 OBU
Phone: 949.608.3900
Tel:
Fax:
949.608.3887
Fax: +44 (0) 1992 467132
Flojet is a trademark of Xylem Inc. or one of its subsidiaries.
© 2012 Xylem, Inc.
81000-290
Rev F 10/2012
Possible Cause(s)
• Air leak in suction line
• Defective check valve
• Upper housing leaking
• Suction lift too high
• Debris in check valve(s)
• Faulty suction piping
• Defective check valve
• Suction lift too high
• Clogged inlet
• Inlet line valve closed
• Voltage incorrect
• Insufficient ventilation for motor
• Piping or hose is damaged
• Clogged check valve
• Worn check valve
• Voltage incorrect
• Tank over pressurized
• Upper housing loose
• Pistons loose
• Pump head loose on motor
• Switch loose
• Defective Diaphragm
• No electricity
• Defective pressure switch
• Motor has open circuit
• Thermal protector has cut off
TO
Liters
Gallons, U.S.
Bar
Pounds/Sq. Inch
Celsius
Fahrenheit
JAPAN
NHK Jabsco Company Ltd.
3-21-10, Shin-Yokohama
Kohoku-Ku, Yokohama, 222
+44 (0) 1992 450145
Tel:
045.475.8906
Fax: 045.475.8908
Corrective Action
• Repair or replace
• Replace
• Tighten bolts
• Lower pump
• Clean check valve(s)
• Repair or replace
• Replace
• Lower pump
• Clean or replace
• Open valve
• Check voltage
• Insure proper ventilation
• Clean or replace
• Clear obstruction
• Replace
• Check voltage
• Check tank pressure
• Tighten screws
• Tighten pistons
• Tighten pump head
• Tighten switch
• Replace
• Check connections, fuse, breakers
• Replace switch
• Replace
• Allow motor to cool 15-30 min
MULTIPLY BY
3.785
0.264
0.069
14.5
(°F-32) .556
(°C X 1.8) + 32
RETURN PROCEDURE
Prior to returning any product to FLOJET, call customer service for
an authorization number. This number must be written on the
outside of the shipping package. Place a note inside the
package with an explanation regarding the reason for return as
well as the authorization number. Include your name, address and
phone number.
GERMANY
ITALY
Jabsco GmbH
Jabsco Marine Italia
Oststrasse 28
Via Tommaseo, 6
22840 Norderstedt
20059 Vimercate, Milano
Tel:
+49-40-53 53 73 -0
Tel: +39 039 685 2323
Fax: +49-40-53 53 73 -11
Fax: +39 039 666 307