1.3 Specifications
Nominal size (Inches)
*Flow range - (LPM) Litres/min
- (GPM) USGal/min
Accuracy @ 3cp
Repeatability
Temperature range
Maximum pressure; Bar (PSI)
(threaded meters)
Protection Class
Display
Recommended filter
Nominal output resolution
Hall Effect (E register only)
Reed
Reed switch output
Hall Effect output (NPN)
* Maximum flow is to be reduced as viscosity increases, see flow de-rating guide
* Maximum flow may be increased by 10% for intermittent refueling periods
Model Prefix
15mm (1/2")
typically ±0.03% of reading
-20⁰C ~ +80⁰C (-4⁰F ~ +176⁰F)
flowrate total (accumulative & resettable)
150microns (100mesh)
Electrical
pulses per litre (pulses per gallon) - Nominal
30vDC x 200mA max
3 wire open collector, 5 ~24vDC, 20mA max
Specifications
D-40
1 ~ 40
0.26 ~ 10.6
±0.5%
40 (580)
IP66/67
168 (636)
84 (31.8)
3