AME 15020 Fiche d'instruction - Page 2
Parcourez en ligne ou téléchargez le pdf Fiche d'instruction pour {nom_de_la_catégorie} AME 15020. AME 15020 5 pages. Air hydraulic pump
CAUTION: Keep hydraulic equipment away from
fl ames and heat. Excessive heat will soften packings
and seals, resulting in fl uid leaks. Heat also weakens
hose materials and packings. For optimum performance do not
expose equipment to temperatures of 65°C [150°F] or higher.
Protect hoses and cylinders from weld spatter.
DANGER: Do not handle pressurized hoses. Escaping
oil under pressure can penetrate the skin, causing
serious injury. If oil is injected under the skin, see a
doctor immediately.
WARNING: Only use hydraulic cylinders in a coupled
system. Never use a cylinder with unconnected couplers. If
the cylinder becomes extremely overloaded, components
can fail catastrophically causing severe personal injury.
WARNING: BE SURE SETUP IS STABLE BEFORE
LIFTING LOAD. Cylinders should be placed on a fl at
surface that can support the load. Where applicable, use
a cylinder base for added stability. Do not weld or otherwise
modify the cylinder to attach a base or other support.
Avoid situations where loads are not directly centered on
the
cylinder
plunger.
considerable strain on cylinders and plungers. In addition,
the load may slip or fall, causing potentially dangerous results.
Distribute the load evenly across the entire saddle surface.
Always use a saddle to protect the plunger.
IMPORTANT: Hydraulic equipment must only be
serviced by a qualifi ed hydraulic technician. For repair
service, contact the Authorized AME Service Center in
your area. To protect your warranty, use only AME oil.
WARNING: Immediately replace worn or damaged parts by
genuine AME parts. Standard grade parts will break causing
personal injury and property damage. AME parts are
designed to fi t properly and withstand high loads.
3.0 DESCRIPTION
The 10,000 psi 15000 Air Pumps have an operating pressure
of 10,000 psi at 85 psi inlet pressure. They are suited for
plant maintenance, fabrication, production, bolting, vehicle
repair, and any task that requires hydraulic pressure from air
input.
SPECIFICATION TABLES
Model
Weight-add 1 lb.
No.
(.5 kg) for bracket
15000
18 lbs. [8,2 Kg]
15020
22 lbs. [10,0 Kg]
15040
40 lbs. [18,1 Kg]
Hydraulic
Hydraulic
Air Ratio
Output Ports
100:1
.375-18 NPTF
Off-center
loads
produce
Reservoir
Capacity
150 cu.in
(2.5 liters)
255 cu.in
(4.2 liters)
2.11 Gal
(8.0 liters)
Oil Flow @
Oil Flow @
100 psi
10,000 psi
(6.9 bar)
(700 bar)
60 cu.in/min.
10 cu.in/min.
(1.0 liters/min.)
(0.16 liters/min.)
4.0 SPECIFICATIONS
See table below.
5.0 INSTALLATION
5.1 Air Supply
Pump operates with 25-125 psi [1,7-8,6 bar] air pressure. A regulator/
fi lter/lubricator should be installed upstream from pump to provide
clean, lubricated air and allow for air pressure adjustment.
5.2 Air Connections
See Figure 1, page 5. Attach air supply to the 1/4 NPT swivel
connection on the end of the pump. Use Tefl on tape or similar
thread sealant. Torque to 20-25 ft. lbs [27-34 Nm].
5.3 Hydraulic Connections
See Figure 2, page 5. Thread hose(s) into outlet port of pump (A).
Hose fi ttings must be torqued.
NOTE: Use 11/2 wraps of Tefl on tape the NPTF hose fi ttings
only, leaving the fi rst complete thread free of tape to ensure that
pieces of tape do not break off and enter the system. Torque: 65-
75 Ft-lbs [88-102 Nm].
NOTE:
Valve block or treadle should be restrained when
torquing fi ttings. The reservoir base should not be bolted down
or restrained to compensate for the fi tting installation torque.
5.4 Venting
This pump must always be vented prior to use. Use either the
"Vent Screw" or "Vent/Fill Plug".
a) Vent Screw: See Figure 3, item 1, page 5. The vent screw is the
primary means to vent the reservoir when the pump is operated
in the horizontal position. It is located near the hydraulic outlet
port on top of the reservoir. To use this plug, open the screw
1-2 turns. To avoid damaging the threads when closing the
vent screw, tighten only until screw head contacts the reservoir
cover. The vent screw can NOT be used when pump is mounted
vertically! When mounting in the vertical position, use the vent/
fi ll plug.
b) Vent/Fill Plug: See Figure 4, item 2, page 5. The Vent/Fill plug
is located on the air inlet end of the pump, opposite the vent
screw. This plug serves 3 functions; vent plug, fi ll port, and
return-to-tank port.
Useable Oil
Horizontal Mount
127 cu.in
(2.1 liters)
230 cu.in
(3.8 liters)
1.85 Gal.
(7.0 liters)
Air Pressure
Range
25-125 psi
( 1,7-8,6 bar)
2
Usuable Oil
Vertical Mount
70 cu.in
(1.2 liters)
180 cu.in
(3.0 liters)
N/A
N/A
Air
Operating
Consumption
Noise Level
100 psi
(dBA)
(6.9 bar)
12 SCFM
76
(0.34 cu.m/min)