AME Intl. 14455 Manuel d'instruction - Page 4

Parcourez en ligne ou téléchargez le pdf Manuel d'instruction pour {nom_de_la_catégorie} AME Intl. 14455. AME Intl. 14455 6 pages. Premium air hydraulic bottle jack

14455 INSTRUCTION MANUAL
PROBLEM
Air pump will not operate
Air pump acts but ram
won't rise
Ram will not rise to highest
position
Ram will lower slowly
Ram will rise slowly
Oil blowing from air pump
Ram will not lower
Phone: (+1) 352.799.1111 • Toll Free (+1) 877.755.4AME (4263)
AME INTERNATIONAL
Release valve not fully closed
Outlet valve dirt or defective
Air pump packing defective
Air pump packing defective
Release valve not fully closed
Air pump packing defective
Release valve/crcuit defective
AME INTERNATIONAL
2347 Circuit Way, Brooksville, Florida USA 34604
Fax: (+1) 352.799.1111 • E-mail: [email protected]
CAUSE
Low air pressure
Air outlet is frozen
Lack of oil
Other
Release valve is open
Lack of hydraulic oil
"Air-bound" system
Other
Lack of hydraulic oil
Filter is full
4
SOLUTION
Keep air pressure between 0.7-
1.0 MPA
Stop using and thaw frozen outlet
Supply oil to air vavle
Contact service center
Close valve clockwise
Supply hydraulic oil
See maintanance
Contact service center
Supply hydraulic oil
Close valve clockwise
Contact service center
Contact service center
Contact service center
Contact service center
WWW.AMEINTL.NET