Inverter Operation
This unit operates on an output voltage of 22V from power source.
2.1
VCC: When On/Off pin of P802 is high level input, Q106 turns on and provides +5VDC for I101 power supply.
2.2
Control IC: I101 (OZ960S)
2.2.1 Enable : When pin 3 of I101 is over 1.5V, I101 works. If it is under 1.5V, I101 turns off.
2.2.2 OSC: When I101 enabled, R108/C115 (pin 17/pin18 of I101) determine the operating frequency.
2.2.3 SST: C104 (pin 4 of I101) provides soft start function.
2.2.4 Ignition: R109 (pin 8 of I101) provides higher operating frequency for more striking voltage until regula-
tion of feedback of lamp current. C103 (pin 1 of I101) determine the striking time.
2.2.5 Dimming control: The divided voltage of R106/R105/R104 control the duty pulse of burst-mode to drive
Q105 and perform a wide dimming control for the CCFL. The burst-mode frequency is determined by C116.
2.2.6 Regulation: Pin 9/pin 10 of I101 provide regulation of the CCFL current from feedback. The non-inverting
reference (pin 10 of I101) is at 1.25V nominal.
2.3
Protection: Open-lamp protection in the ignition period is provided through both pin1 and pin 2 of I101 to ensure
a rated voltage is achieved and a required timing is satisfied.
Removal of the CCFL during normal operation will trigger the current amplifier (pin 9/pin 10 of I101) output and
shuts off the inverter. This is latch function.
2.4
2.4.1 Output drivers: The configuration prevents any shoot-through issue associated with bridge-type power
conversion applications. Adjusting the overlap conduction between I102 P-MOSFET and I103 N-MOSFET,
I101 N-MOSFET and I103 P-MOSFET, the CCFL current regulation is achieved.
2.4.2 Full-bridge switching/Transformer: I102/I103 /C123/T101 compose full-bridge switching to convert DC
into AC for driver the CCFL.
2.5
Detection: C128/C129/C132/D115/D114/C118 detect the output voltage and ensure a rated voltage by pin2 of
I101.
2.6
Feedback: D116/D117/R120/D108/R116 sense the lamp current for negative feedback and regulation. The divided
voltage on R116 will be at 1.25V.
VCC
Regulator
ON / OFF
U.V.P.
Brightness
control
Page 4
Inverter Circuit Block Diagram
VDD
Control IC : OZ960
Enable
Output driver
OSC
Protection
SST
Ignition
Dimming
Regulation
control
Full-bridge switching
Transformer
Detection
Feed back
AL1702