A voltage of 2V to pin10 of IC501 enables the IC and activates the striking timer. The SSTCMP
pin of IC501 performs the soft function, the C511 set the time of SST. The operation frequency
determined by external capacitor C512, C521 and resistor R508 connected at CT pin of IC501.
C515 connect the TIMER pin of IC501, the capacitor to set striking time and shunt down delay
time. DRV!, DRV2 output for power MOSFET U501, U502.
OZ9938 provides two drive signals for U501, U502, and they work in push pull topology
driving, two transformers are connected in parallel with each transformer driving two lamps in
series. Turning each N-Channel MOSFET "on/off" complementarily, produces an alternating
current through the transformer primary and secondary. The "on" duration of the switches
determines the amount of energy delivered to the CCFLs. R504, C504, R505, C505, R532, C529,
R530, C522 are snubber networks, they suppress Voltage transient spike in drain of power
MOSFET.
R506, R510, C509, C513, C514, R525, R531, C528, C525, and C527 are connected between
high voltage output connector and ground, the divided AC voltage is inverted DC voltage through
D502, D503, D508, and D509. The sense voltage feed back to VSEN (pin 6 of IC501) for an over
voltage/over current condition during normal operation. R528, R533,R523,R536 are current sense
resistor, current sense signal feed back to Isense (pin 5 of IC501) for lamp "ON" detection.