1.1
Mounting
The Model 81096 is designed to be mounted in a standard 19" relay rack. Control
and input wire lengths are not critical so the unit can be mounted in a convenient
location offering easy accessibility and viewing.
When mounting, be sure to use proper grounding techniques. Interlock wiring should
be shielded and the chassis ground connection on the Watchman should be
attached to a good ground, preferably to the same ground used for the transmission
line.
Place the unit in the rack and secure with (4) four screws located in the slots
provided. The line section may be mounted in the transmission line between the
transmitter output and the antenna or between the driver and final output transmitter.
The latter provides protection in the event a malfunction in the input circuits of the
final transmitter.
The Model 81096 is designed to work with a series of specialized line sections from
7/8" to 6-1/8" and standard Coaxial Dynamics elements for either analog or digital
applications. Elements are available from 1 W to 250 kW and from 2 MHz to 1800
MHz. A typical system normally consists of a dual socket line section with the
appropriate elements for each transmission line to be monitored. Each line section
comes with a 10-foot telecommunications style cable to interface with the 81096. No
additional power supply or cabling is required at the line section other than an RF
source and load.
1.2
Connections
Connections to the Model 81096 terminal strip are as follows:
10-32 Stud
Pin #1
Pin #2
Pin #3
Pin #4
Pin #5
Pin #6
Pin #7
Pin #8
Pin #9
Pin #10
Pin #11
Pin #12
Model 81096
SECTION 1 - INSTALLATION
Ground Stud to Station Ground
Remote Reset – Momentary to Ground
+5 VDC @ .25 A
System Ground
Common System, Control relay – common to 5 and 6
Common System, Control relay – N.C.
Common System, Control relay – N.O.
System 1, Control relay – common to 8 and 9
System 1, Control relay – N.C.
System 1, Control relay – N.O.
System 2, Control relay – common to 11 and 12
System 2, Control relay – N.C.
System 2, Control relay – N.O.
- 4 -
8/2019