AeroBed 103H-AU Manuel d'instruction - Page 3
Parcourez en ligne ou téléchargez le pdf Manuel d'instruction pour {nom_de_la_catégorie} AeroBed 103H-AU. AeroBed 103H-AU 4 pages.
SERVICING OF DOUBLE-INSULATED PRODUCTS
In a double-insulated product, two systems of insulation are provided instead of grounding. No grounding means is provided on a double-
insulated product, nor is a means for grounding to be added to the product. Servicing a double-insulated product requires extreme care and
knowledge of the system, and is to be done only by qualified service personnel. Replacement parts for a double-insulated product must be
identical to the parts they replace.
INFLATION
NOTE: BED MUST BE AT ROOM TEMPERATURE PRIOR TO INFLATING OR IT MAY CAUSE AIR LEAKS.
Remove your AeroBed
product from its lightweight duffle bag. Keep bag for storage.
®
1. Place your rolled-up bed on the floor free of obstructions or sharp objects.
2. Make certain the Quick Air Release Valve located at the head of the bed is closed. If the Air Release Valve is open, close it by using 2
thumbs to push cover and snap into valve. Be careful to avoid pushing valve cover to the right or left as it snaps into the valve opening.
3. Remove AC pump and cord from protective plastic shipping wraps.
4. This product has a polarized attachment plug (one blade is wider than the other) as a safety feature. This plug will fit into a polarized outlet
only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Never use with
an extension cord unless the plug can be fully inserted. Do not attempt to defeat this safety feature.
IMPORTANT: Always operate the product from a power source of the same voltage, frequency, and rating as indicated on the product
identification plate.
5. Remove protective plastic cap from the Quick Air Release Valve by turning counter clockwise.
Open the protective rubber cap at the end of the pump. Press mouth of the pump into position
on the Quick Air Release Valve and turn clockwise until it locks.
6. A one-quarter turn clockwise automatically starts inflation.
7. At approximately 60 seconds, a high pitch whine of the pump will signal the bed is inflated to
full (firmest) capacity. Bed will not over-inflate.
8. Detach pump by turning counter clockwise. Lie on bed and check the firmness. If you want your bed to be softer, depress the button in the
center of the valve. If the bed becomes too soft, reattach the pump and reinflate the bed until the desired level of firmness is achieved.
IMPORTANT: Be sure to close the protective cap after inflation.
DEFLATION AND STORAGE
1. Open the Quick Air Release Valve cover at the head of the bed to release the air.
2. Fold sides of bed into the center along its length. Tightly roll your bed towards the Quick Air Release Valve at the end
of the bed.
3. Roll the bed completely until all air is expelled. When the bed is completely rolled, push the Quick Air Release Valve
closed and locked for its next use.
4. Slide the duffel bag over your AeroBed
CARE AND MAINTENANCE
1. Inspect your AeroBed
product prior to each use.
®
2. Keep your AeroBed
®
product away from any sharp objects. Large cuts or snags may not be repairable and will not
be covered by your warranty.
3. When not in use, store your AeroBed
Note: Bed must be at room temperature prior to inflating or it may cause air leaks.
4. In case of incidental damage to your bed, repair patches have been included. Please follow repair instructions carefully.
CLEANING
We recommend that you do not let the plush surface of your AeroBed
cause damage to the plush surface that will not be covered by your warranty. Should liquid come in contact with the plush surface, blot
liquid dry and use a damp cloth to remove any stain. Let surface air dry completely. You may clean the PVC on the sides and bottom of your
AeroBed
product with a mild dishwashing detergent or household cleaner. Do not use strong chemicals or other compounds. Allow your bed
®
to air dry completely after cleaning and before storing.
CAUTION: To reduce risk of electric shock, do not immerse or expose the adaptor/charger, pump motor, or flexible cord to water, rain, or
any other liquid, or charge the pump near baths, basins, or other vessels containing water or other liquids, or when standing in or on damp
or wet surfaces. If any electrical product falls into water, or if water should accidentally enter the pump motor or adaptor/charger, UNPLUG it
immediately; DO NOT REACH INTO THE WATER. Important: Prior to reconnecting to the power supply, the product should be inspected by a
qualified technician.
This is the closed position.
Open Air Release Valve. Close Valve Using 2 Thumbs.
product. Store your bed and pump until its next use.
®
product in a clean, dry place out of extreme temperatures.
®
®
product get wet. Repeated exposure to water or other liquids may