123Filter iSpring Instructions d'installation - Page 12
Parcourez en ligne ou téléchargez le pdf Instructions d'installation pour {nom_de_la_catégorie} 123Filter iSpring. 123Filter iSpring 15 pages. Reverse osmosis water filter systems
Également pour 123Filter iSpring : Manuel du propriétaire (9 pages)
8.6 Shut off the RO Drinking Faucet. Turn on the Tank Shut-off Valve. Wait for the tank to be filled up. It may
take 1.5 hours in warm summer or 3 hours in cold winter to fill up a 3.2 gallon tank with about 2.5 gallons
holding capacity.
8.7 After two hours, turn on the RO Drinking Faucet to flush out all the water in the tank. DO NOT use the first
tank of water. The water out of the faucet should be a much stronger stream since the water pressure was
built up to 35-40 psi when being filled up. When the water flow changes back to a trickle, it means the tank is
empty.
8.8 * Plug in the UV power and observe if the RO faucet turns the UV on/off through the Flow Sensor Switch.
8.9 The reverse osmosis membrane is the key part for the effective reduction of total dissolved solids (TDS) and
that product water shall be tested periodically to verify that the system is performing properly. If the TDS of
the source water is 100ppm, the RO water should be less than 10ppm (Rejection rate >90%).
8.10
Check for leaks daily for the first two weeks after installation. Furthermore, a bucket can be put
under the system in case of any leaks, and a Flood Alarm can be used together for better protection.
Congratulations! You have successfully installed the
iSpring Reverse Osmosis Water Filtration System!
Start enjoying the cleanest water right from your tap!
www.123filter.com
| (678) 261-7611
Page 11