1. Unplug the water pump and fan.
2. Close the automatic water inlet valve.
3. Disconnect the pump discharge water line.
4. Clean or replace the line and pump as needed.
5. This should clear any blockage in the CAP.
6. Reattach water line.
H. Vacation or Intentional Shut Down
When not in use for an extended period (to shut down):
1. Disconnect the water pump;
2. Close the automatic water inlet lines.
3. Drain out each reservoir's water by opening the drain valve over a suitable drain or collect in a suitable
container.
4. Allow to dry by running fan for a few hours or overnight.
5. Disconnect fan.
You can store the CAP for years in this manner. When ready to re-use, just refill with water, add BioOx
and start up.
I. Maintenance
Every six months (or as needed), maintain your CAP as follows:
Clean out the water in the CAP using the following procedure.
1. Unplug the fan and the water pump.
2. Drain the water reservoir into an adequate container by opening the drain valve, or using a special pump or
wet/dry shop vac.
3. Flush several gallons of tap water into the blue hose connection at the top of the unit below the fan housing, so
that the water flow can clear any accumulated debris.
4. Repeat steps 1-4 until the water dumped out from the CAP is clear.
5. Refill with water. Add BioOx
J. Question or comments regarding your CAP should be directed to:
Air & Water Solutions, Inc.
P.O. Box 627
Nutley, NJ 07110
Tel. : 973-661-5192
Fax : 973-661-3713
www.cleanairplant.com
®
enzymes.
®