One of the three editable light parameters
is selected by pressing the encoder knob (8). The currently selected parameter is marked with ">"(10).
Turning the dial (8) changes the value of the currently selected parameter.
Turning to the right increases the parameter and turning to the left decreases it.
Approximately two seconds after stopping turning the knob, the controller switches the automatically adjustable parameter to the default one. In CCT mode, the default parameter to edit is DIM, and in HSV
mode, the VAL parameter. In RGB mode, automatic restore to default parameter does not work.
The encoder knob (8) has a dynamic precision control.
Slowly turning the knob changes the adjustable parameter by one step, for each step of turning the knob.
Faster turning speeds up the regulation, with the number of regulation steps per knob step being dependent on the turning speed. This makes it possible to achieve the desired parameter value with a small
knob stroke and at the same time to set the selected parameter precisely.
TUN/GREEN button function (6)::
- in CCT mode, pre-selects light tungsten CCT = 3200K GM = 0 (OFF), DIM - no change
- in RGB mode, it loads the green light: R = 0, B = 0, G - the maximum of the current RGB values
- in HSV mode, it loads the green light: HUE = 120°, SAT = 100%, VAL- the current value
DAY/BLUE button function (7):
- in CCT mode, it preselects daylight CCT = 5650K GM = 0 (OFF), DIM - no change
- in RGB mode, it loads blue light: R = 0, G = 0, B - the maximum of the current RGB values
- in HSV mode, it loads the blue light: HUE = 240 °, SAT = 100%, VAL - the current value
10
4
5
6
7
S E C T O R
Fig.2
SECTOR Controller buttons