6. Insert the Bathroom Heater unit into the square hole, ensuring that the side springs are pulled inwards so that the unit can pass
through the hole, without damaging the plaster.
7. Securely fix the unit with the clips, and if required, additional screws can be used to assist unit retention in the ceiling. NB: Screw
holes are provided in the flange for this purpose.
8. Re-assembly is the opposite of dis-assembly.
9. For installation where external venting is required or is your choice, select a suitable location in either the roof or exterior wall to
vent out the exhausted air/steam and cut out a 155mm hole.
10. Put the ventiduct into the vent hole and seal the space around the hole using a suitable sealant and cowling where necessary.
11. Fit the in-house end of the duct to the fan outlet, and fix the end with duct clip. Ensure that the ducting is kept as straight as
possible.
ELECTRICAL WIRING
NB: This unit is fitted with a thermostat switch which will operate to
automatically switch the exhaust fan on, in the event that the heat
globes are left on, and the internal temperature of the unit exceeds
90ºC
1. Ensure that the power is turned off before carrying out any work
on electrical installations.
2. Clip the switches to the backing plate in the desired order, and
install the plate onto the wall.
3. Connect the wiring to the three switches as per the electrical
diagram.
4. Remove the terminal cover on the heater unit, and wire according
to the label adjacent to the terminal block. Ensure all cables are
securely connected before refitting the terminal cover.
5. Clean the facia and globes with a soft damp cloth, and switch the
unit ON, checking operation of all functions.
OPERATION
Your Brilliant Bathroom Heater uses InfraRed heating lamps as a source of heat. It also combines the functions of exhaust and light.
Heating:
• Turn on/off 'Heat' button/s.
• Your Bathroom Heater is supplied with two InfraRed lamps. You can turn both of them on for best heating effect.
Exhaust Fan:
• Turn on/off "fan" button
• Your Bathroom Heater will exhaust odours and steam in a quick and efficient manner.
Lighting:
• Turn on/off "light' button to activate the central LED light.
CLEANING
• Switch off power before commencing cleaning, and allow unit to cool to room temperature.
• Regularly wipe globes and fascia using a soft cloth soaked with neutral detergent. Ensure the globes have cooled to room temperature
before handling.
• Ensure Lampholders are free from any foreign objects and/or dust.
• The centrifugal fan requires regular cleaning to ensure optimum performance. With the power OFF, regularly wipe the fan clear of all
dust and dirt.
• Clean the exhaust ducting kit, ensuring there are no obstructions at the exit.
• Use only a soft damp cloth to clean your Brilliant Bathroom Heater. If detergents are required, use only a neutral detergent that will
not damage the facia.
Note:
-The lamp must be installed by professional electrician
-Ensure the power supply is switched off before fitting this product
29-31 Richland St. Kingsgrove. Sydney NSW 2208 Australia
Phone: 02 9554 9600 | Fax: 02 9554 9433
[email protected] | www.domuslighting.com
Wiring Diagram
c
IN
M: Motor C: Capacitor IR: Heat lamp IN: Light lamp
K: All-pole disconnection switch
-Do not touch the lamp when in use
-Keep away from hot steam and corrosive gas
Installation Manual
Back Side
FAN
Exhaust
LIGHT
Light
HEAT
Heat
N
K
E
E
: Heat protector
L
N