American Standard Selectronic Innsbrook Electronic Lavatory Faucet 6057.205 Manuel d'instructions d'installation - Page 9

Parcourez en ligne ou téléchargez le pdf Manuel d'instructions d'installation pour {nom_de_la_catégorie} American Standard Selectronic Innsbrook Electronic Lavatory Faucet 6057.205. American Standard Selectronic Innsbrook Electronic Lavatory Faucet 6057.205 12 pages. American standard selectronic innsbrook electronic lavatory faucet speciifcation sheet
Également pour American Standard Selectronic Innsbrook Electronic Lavatory Faucet 6057.205 : Liste des pièces (1 pages), Fiche technique (1 pages)

American Standard Selectronic Innsbrook Electronic Lavatory Faucet 6057.205 Manuel d'instructions d'installation
HOW TO CLEAN FILTER; Fig. 4
4
Before opening ENCLOSURE
CAUTION
disconnect AC power supply.
1. Remove ENCLOSURE COVER.
2. Close SUPPLY STOP (5) with 4mm Hex wrench.
Note: Keep water flowing out of faucet while shutting off.
3. Pull off Red (1) and Black (2) CONNECTORS from

SOLENOID VALVE (3).

4. Unthread STRAINER (4) using a 7/16" socket.
5. Pull out the STRAINER (4) and clean with an old
toothbrush. Rinse thoroughly with water.
6. Install the STRAINER (4) back in its place and
tighten with a 7/16" socket.
Caution: do not over tighten strainer.
Note: It is recommended to clean strainer every 6
months.
7. Replace ENCLOSURE COVER. Tighten cover
screws firmly.
HOW TO CLEAN AND REMOVE
5
THE AERATOR; Fig. 5
1. Remove AERATOR HOUSING (1) with KEY
supplied with faucet.
3. Remove AERATOR (2) from HOUSING (1).
2. Clean the AERATOR SCREENS (3) with a old tooth
brush to remove dirt.
4. Rinse Clean with water. Reassemble and install into
spout end. Be sure black seal washer is in place.
GENERAL CLEANING; Fig. 6
6
1. For general cleaning use a damp, soft cloth to clean
the spout and the sensor.
2. For cleaning dirt use a soft cloth with diluted dish
washing detergent. Wipe the area using a wet cloth
and dry using a soft cloth.
CAUTION
Do not scratch the sensor when cleaning.
Avoid using anything that may scratch the spout
surface. Never use polishing power, detergent or a
nylon scrub brush. They will damage the surface of the
spout or Sensor.
Fig.4
2
5
1
Fig.5
Fig.6
8
3
4
CLEAN
SCREENS
4
1
3
2