Barox PC-IA500 Manuel de l'utilisateur - Page 2
Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} Barox PC-IA500. Barox PC-IA500 7 pages. Industrial switch
Introduction
This hardened designed industrial 5 port 10/100M Ethernet Switch is equipped with wide range VDC
power input. It is suitable for heavy usage areas such as hazardous environments or central control
place where a reliable device is critical. It is an ideal solution for Industrial Automation, IP surveillance,
traffic monitoring and a wide range of applications. It has been rigorously tested for your Security,
Transportation and Telco applications.
Installation package
This unit can be din-rail mounted or wall-mounted. Din-rail brackets and wall-mounted brackets are
included.
Wall mount
bracket x 2
Power connection
This unit comes with a 4 pin terminal block. It can be operated from 12-56VDC power source. Always
make sure your input voltage is within this supported voltage range for each model
WARNING -- Any exceeded input voltage will not make this unit function and may damage this unit.
To connect power: This unit supports two power inputs. Follow the printed polarity for +V1-, +V2- and
ground. Connect positive wires to V+, connect negative wires to V-, and connect a neutral wire to the
ground screw.
+V1- is for power input one connection.
+V2- is for power input two connection.
6 pin Terminal Block x1
Philips Head Screw x 4
Din Rail Bracket x 1
Page 2/7