Physical and Operating Specifications
n
Physical Specifications
SIZE: 6.31 in.(16.03 cm) W
2.62 in.( 6.65 cm) H
6.78 in.(17.22 cm) D w/ connector
CONTROLS: Panel mounted - transmit = rotary switch, audio inputs = toggle switch
volume control = dual potentiometer
ILLUMINATION: Edge lit front panel per MIL-P-7738E, type 3. Capable of connection to
Operating Specifications
n
INPUTS: 5 receive audio inputs per position. 6 transmit selections per position.
DUTY CYCLE: Continuous
MAXIMUM OPERATING ALTITUDE:
OPERATING TEMPERATURE RANGE:
CURRENT DRAIN: 50 mA at 28V (standby) - 1.5 A at 28V (max. signal)
AUDIO OUTPUT: Minimum 250 mW into 600 ohms
FREQUENCY RESPONSE: Within 6 db - 300-3000Hz
ICS INPUT IMPEDANCE: 600 ohms
RECEIVER INPUT IMPEDANCE: 600 ohms - matched to receiver
INPUT ISOLATION: Not less than 45 db between inputs
AUDIO MUTING: Not less than 45 db during transmit/ICS (optional)
MIC SENSITIVITY: 300 mV for rated output
DISTORTION: Less than 10% at 1000 Hz for maximum output
Air Comm Systems, Inc.
MOUNTING: Dzus rail mount
dimmer bus for adjustment. Amber transmit light indicates when unit is in
transmit mode.
POWER REQUIREMENTS: 14V DC or 28V DC +/- 10%
WEIGHT: 2.90 lb
16,500 ft.(5029 m)
-40 C to +85 C (operating)
-65 C to +125 C (storage)