Da-Lite Cosmopolitan Electrol Manuel d'instruction
COSMOPOLITAN ELECTROL INSTALLATION
120V WIRING DIAGRAM
TO JUNCTION BOX, MOUNTED IN
SCREEN CASE, IN WHICH INTERNAL
WIRING TERMINATES IN WHITE,
BLACK AND RED LEADS
BLACK
ROCKER
SWITCH
UP
OFF
DOWN
SIDE VIEW
OF SWITCH
AND BOX
THIS SWITCH CANNOT BE USED WITH LVC.
NOTE: A single switch cannot be used to operate more than
one screen. Contact the factory for further information.
220 / 240V
WIRING DIAGRAM
TO JUNCTION BOX, MOUNTED IN
SCREEN CASE, IN WHICH INTERNAL
WIRING TERMINATES IN BLUE,
BROWN AND BLACK LEADS
UP
OFF
ROCKER
SWITCH
DOWN
REAR VIEW OF DPDT,
WITH CENTER OFF.
NOTE: A single switch cannot be used to operate more than
one screen. Contact the factory for further information.
UP YELLOW LIMIT
SWITCH ADJUSTMENT
AND DOWN WHITE
LIMIT SWITCH
ADJUSTMENT
WHITE
RED
BLACK WITH
OPERATING SWITCH, SWITCH
YELLOW
BOX, AND PLATE FURNISHED
WITH SCREEN. (SPDT WITH
CENTER OFF)
AC COMMON
AC HOT
120 V. 60 HZ. 2.5 MAX. AMP
UP YELLOW
LIMIT SWITCH
ADJUSTMENT
AND DOWN
WHITE LIMIT
SWITCH
ADJUSTMENT
OPERATING SWITCH, SWITCH
BOX, AND PLATE FURNISHED
WITH SCREEN.
BROWN /YELLOW
BROWN AC HOT
BLUE AC COMMON
220/240 V. AC 50 HZ.
2 AMP MAX.
BLUE JUMPER WIRE
WIRING ENCLOSURE COVER
IN MULTIPLE CONTROL INSTALLATIONS
THIS SWITCH IS REPLACED BY THE LOW
VOLTAGE CONTROL, OPERATED FROM
PUSH BUTTON STATIONS.
WIRING ENCLOSURE COVER
NOTE:
MUST BE WIRED TO CONFORM TO LOCAL WIRING
CODE. THIS SWITCH CANNOT BE USED WITH L.V.C.
IN MULTIPLE CONTROL INSTALLATIONS THIS
SWITCH IS REPLACED BY THE LOW VOLTAGE
CONTROL, OPERATED FROM PUSH BUTTON
STATIONS.
JUNCTION
BOX
3
FIGURE 3
FIGURE 3