Tensioned Cosmopolitan
240V Wiring Diagram
With Optional Built-In
Low Voltage Control
Blue (Common)
Brown (Hot)
240VAC 50Hz
Green
Ground–Must be
Connected to
Building Ground
ILT RJ9 Pin-Outs
IR or Up
Ground Common
+5V
DN or Data

Screen Adjustment

The screen surface travel is stopped automatically in the fully opened and closed positions by limit switches that are properly
adjusted at Da-Lite. The screen should not be adjusted for more or less drop. The fabric cables are adjusted for proper vertical
and lateral tension at Da-Lite.
CAUTION! Contact Da-Lite at 800-622-3737 or 574-267-8101 if screen motor needs adjustment.
ATTENTION! Contactez Da-Lite au 800-622-3737 ou au 574-267-8101 au cas le moteur de l'écran a besoin d'être ajusté.
6
Electrol
Installation
®
®
Green
Ground to Case
(Tab Is Facing Up)
Black
Red
Green
White
Connect Supplied RJ9 Cable
to Splitter and Switch, or use
4 Cable Conductor to Connect
Optional IR and RF
Remote Control
Motor
RJ9
Splitter
Dry Contacts
IMPORTANT NOTE: The wall switch is REQUIRED to make
any limit switch adjustments, EVEN if a third party control
system is used. Therefore, it is advised to wire the switch or
provide a 4-conductor connection that is accessible.
to Screw Terminals.
Low-Voltage Wall Switch
Up
RJ9
Stop
Down
Front
UP DN
GND +5V
3-Position
RJ9
Switch
Back