American Standard Cadet 2771.XXXW Series Instructions d'installation
Parcourez en ligne ou téléchargez le pdf Instructions d'installation pour {nom_de_la_catégorie} American Standard Cadet 2771.XXXW Series. American Standard Cadet 2771.XXXW Series 4 pages. 5' x 36" whirlpool/bathing pool
CADET™ 5' x 36"
HIGH GLOSS ACRYLIC
SHOWN LESS ALL FITTINGS
305 mm
(12)
235 mm
(9-1/4)
19 mm
(3/4)
FINISHED
WALL
SEE FITTING
SPECS FOR
DIMENSIONS
914 mm
(36)
457 mm
(18)
C/L OF
57 mm
SUPPLIES
(2-1/4)
C/L OF DRAIN
OPTIONAL TO
FINISHED FLOOR
USUALLY BETWEEN
1651 & 1981mm
(65 & 78)
C/L OF
OVERFLOW
38 mm
(1-1/2)
76 mm
(3)
502 mm
(19-3/4)
ROUGH
FLOOR
INTEGRAL
SUPPORT
FEET
GENERAL SPECIFICATIONS FOR 2771 WHIRLPOOL
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
MIN. OPERATING GAL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT
3
)
WHIRLPOOL ELECTRICAL SPECIFICATIONS
PUMP
GENERAL INSTALLATION INFORMATION
Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor
immediately.
After inspection and during installation, protect the bath from construction damage. After installation, and before
enclosing with wallboard, tile, etc., water test the unit and check for leaks.
Do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect
the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump,
motor, or piping system.
Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and
enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead
(required for recess installations).
Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.
WARNING! Do not lift whirlpool by the piping harness at any time.
FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.
752500-100 REV. G
2771.XXXW SERIES
WHIRLPOOL/BATHING POOL
INSTALLATION INSTRUCTIONS
PROVIDE ACCESS TO PUMP FOR
SERVICING ON ALL INSTALLATIONS
1524 mm
(60)
RECOMMENDED FITTING LOCATION
64 X 330mm (2-1/2 x 13")
FOR PIER OR ISLAND
INSTALLATIONS ONLY
229 mm
(9)
PUMP
CUTOUT IN FLOOR
FOR DRAIN
(8) JETS
(2) AIR VALVES
OUTLINE OF CUTOUT
1486 mm x 876 mm
ALT. FITTING
(58-1/2 X 34-1/2)
LOCATION #1
C/L OF
SHOWER ARM
C/L OF
VALVES
C/L OF
305 mm
SPOUT
(12)
SAFE-T-HEATER
102 mm
REMOVABLE
(4)
BLANK
464 mm
(18-1/4)
1-1/2 N.P.T.M.
THREADS
70 mm
(2-3/4)
1-1/2 O.D.TAILPIECE
117 mm
(4-5/8)
60 x 36 x 19-3/4 In.
(1524mm x 914 mm x 502mm)
95 Lbs. (43 Kg.)
587 Lbs. (267 Kg.)
59 Gal. (224 L.)
48 Gal. (182 L.)
40 x 22 In. (1016mm x 559mm)
52 x 29 In. (1321mm x 737mm)
13-1/4 In. (337mm)
39 Lbs./Sq. Ft. (188 Kgs/Sq. m.)
23.8
44.5
1.6 HP, 9.7 AMPS, 120V.
THANK YOU...
for selecting an American Standard bath. Your new
ON/OFF
SWITCH
bath is shipped to you after careful inspection. The
whirlpool version is completely assembled with pump,
motor, and system piping. All you need to finish the
installation are your selected fittings and electrical
connections for a whirlpool.
To insure maximum performance and pleasure from
this product, please follow the instructions and
cautions.
List of Optional Components (not included):
• Safe-T-Heater 9075.120*
• Tile Bead Kit - 751755-100*
• Apron Kit*
LEVELING
STRINGER
List of Required Components (not included):
NOT FOR
SUPPORT
• Drain 1583.470*
* see your American Standard Distributor
List of Required Tools and Supplies:
Tools
• Level
• Tape Measure
• Pipe Wrench
• Slip Joint Pliers
• Screw Driver
• Standard
Woodworking Tools
• Personal Safety
Equipment
• Caulking Gun
• Bath Filler*
Supplies
• Nails
• Putty
• Caulking (waterproof)
• 1 x 3 or 2 x 2
• Drop Cloth
• 15 amp GFI
• Cement, Plaster,
© American Standard Inc. 2003
All product names listed herein are trademarks
of American Standard Inc. unless otherwise noted.
Stringers
Outlet
Grout