American Standard Ariana 6022 Instructions d'installation
Parcourez en ligne ou téléchargez le pdf Instructions d'installation pour {nom_de_la_catégorie} American Standard Ariana 6022. American Standard Ariana 6022 4 pages. In wall pressure balancing bath and shower sets
ARIANA
IN WALL PRESSURE BALANCING
BATH AND SHOWER SETS
Thank you for selecting American-Standard...the benchmark of fine
quality for over 100 years.
To ensure that your installation proceeds smoothly--please read these
instructions carefully before you begin.
ROUGHING-IN DIMENSIONS
To assure proper positioning in relation to wall,
note roughing-in dimensions.
FINISHED WALL
5-1/8" REF.
7-7/8" REF.
74" FOR HEAD
CLEARANCE
18" OPTIONAL
4-1/4"
5" REF.
TOP OF TUB RIM
BOTTOM OF TUB
1
ROUGHING-IN
When soldering, remove PLASTER GUARD, CARTRIDGES and CHECK STOPS (IF PRESENT). When finished soldering,
NOTE
flush valve body, replace cartridges, check stops (if present) and plaster guard to continue installation. Use thread
sealant or Teflon tape on threaded connections.
See Roughing-in diagram before starting.
Connections are:
1/2" female NPT for threaded inlets
Connect RISER PIPE (1) to MANIFOLD (2)
top outlet marked "SHR".
Connect TUB FILLER PIPE (3) at bottom
outlet marked "TUB".
For proper positioning the finished wall
must be within side wall of PLASTER
GUARD (4).
1/2" NPT
1-5/8"
to
3-1/4"
OPTIONAL TO FINISHED
FLOOR USUALLY
BETWEEN 65'' AND 80''
7-1/8"
REF.
4"
1/2" NPT
CAUTION
Turn off water at main supply.
If the valve is installed on a fiberglass
or other thin wall application, the
PLASTER GUARD (4) can be used as a support.
Connect hot and cold water supplies.
Cap off shower pipe (5) and tub filler pipe (6).
For support, use pipe BRACES (7) secured to wooden braces.
With valve turned off, turn on water supplies. Check for leaks.
Installation
Instructions
6021
6022
Required Tools
Phillips Screwdriver
Plumbers' Putty or Caulking
INLETS 1/2" NPT
3-3/8"
3-3/8"
OUTLETS
1/2" NPT
THREADED INLETS
Cut a 3" dia. hole in the shower stall.
Drill two additional 1" holes to allow access
to the stops.
Remove PLASTER GUARD (4), rotate 90˚
so that indicated screw holes fit MANIFOLD (2).
Push CAP on valve, place ESCUTCHEON on and
attach with screws.
Certified to comply with ANSI A112.18.1
M 9 6 8 4 5 7 B
Flat Blade Screwdriver
Adjustable Wrench
Channel Locks
OUTLETS
1/2" NPT
5-7/8"
3-3/8"
THREADED INLETS (STOPS)
1
COLD
2
HOT
3
INLETS
1/2" NPT
5
7
4
6