American Standard ACONT203AS42MA Manuel d'installation et d'utilisation - Page 5
Parcourez en ligne ou téléchargez le pdf Manuel d'installation et d'utilisation pour {nom_de_la_catégorie} American Standard ACONT203AS42MA. American Standard ACONT203AS42MA 20 pages.
4.5
Wiring Diagrams
1 or 2 Stage Heat Pump with TAM7/TAM9 (24V Mode)
Thermostat
Rc
Rh
O/B
Y
G
W/E
C
L
Y2
W2
1 or 2 Stage Cooling with TAM 7/TAM 9 (24V Mode)
Thermostat
Rc
Rh
O/B
Y
G
W/E
C
L
Y2
W2
Pub. No.
11-HD19D1-1D-EN
Indoor Unit
R
O
Y1
G
W1
B
Y0
Y2
W2
W2
W3
W2
W2
BK
Indoor Unit
R
O
Y1
G
W1
B
Y0
Y2
W2
W2
W2
W3
W2
BK
09/2020
Part No. 37-7777006
American Standard 203 Programmable Thermostat
Outdoor Unit
NOTES:
1) Wire third party condensate over ow
switches between Y of the thermostat
and Y1 of the air ow control board
2) X2 is required to energize aux heat
during defrost
Outdoor Unit
NOTES:
1) Y1 and Y0 connections must be made as shown
for freeze protection and internally mounted
condensate over ow circuits to function properly.
2) Wire third party condensate over ow switches
between Y of the thermostat and Y1 of the air ow
control board
R
O
X2
B
Y/Y1
Y2
R
B
Y/Y1
Y2
5