American Standart Reliant 3 TU385500WD Instructions d'installation - Page 3
Parcourez en ligne ou téléchargez le pdf Instructions d'installation pour {nom_de_la_catégorie} American Standart Reliant 3 TU385500WD. American Standart Reliant 3 TU385500WD 4 pages. Pressure balancing bath and shower trim kit
4
ADJUST HOT LIMIT STOP
• By restricting HANDLE rotation and limiting the amount of hot water
allowed to mix with the cold, the HOT LIMIT SAFETY STOP (1)
reduces risk of accidental scalding. To set the maximum hot water
temperature of your faucet valve, adjust the setting on the HOT LIMIT
SAFETY STOP (1).
• Turn CARTRIDGE STEM (2) to the OFF position (coldest setting) before
making adjustment to HOT LIMIT STOP (1). Pull forward and rotate
counterclockwise one number to limit hot water temperature.
Use NUMBERS (5) on CARTRIDGE (4) on HOT LIMIT STOP (1)
for indication.
5
SERVICE
TO GAIN ACCESS TO VALVE FOR SERVICING
• Remove HANDLE (see step 3 and reverse).
• Remove ESCUTCHEON and CARTRIDGE CAP (see step 1 and reverse).
VALVE LEAKS WHEN SHUT OFF
• Remove CARTRIDGE, see STEP 1 and STEP 2 and REVERSE process.
• Clean SEALS on the side of CARTRIDGE. Clean inside sealing surface of VALVE BODY.
• Re-assemble CARTRIDGE. Install trim. Turn on water supply and check for leaks.
REPLACING CARTRIDGE
• To remove CARTRIDGE (1), install split WASHER (3) between the ridge on the cartridge and the bonnet nut (only
supplied with replacement cartridge) as shown.
• Proceed to unthread BONNET NUT (2) counter clockwise.
Note: CARTRIDGE (1) should be pulling out while unthreading BONNET NUT (2).
Upon removal of the old Cartridge, install a new cartridge and secure it with
•
(Hand tighten).
BACK TO BACK INSTALLATION
• NOTE: Must purchase specialized back to back cartridge. (Part number M970640-0070A)
• Remove CARTRIDGE (1) as detailed in steps above.
• Install back to back cartridge.
6
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
CAUTION
Figure 1.
- 3 -
5
4
1
COLDER
(Larger Numbers)
1 2 3 4 5 6 7 8 9 10
Turn off hot and cold water
supplies before beginning.
BONNET NUT
2
1
2
HOTTER
(Smaller Numbers)
1 2 3 4 5 6 7 8 9 10
3
3
M965937 Rev. 1.0 (12/18)