5.7. Brake
Load braking performance depends on the road conditions and equipment.
Brake function can be activated by the following ways through the accelerator button (12) moved
back to '0' position or the release of this button, the regenerative braking is activated.
Through the accelerator button (12) driving direction move directly to the opposite direction from a
truck with regenerative braking, until it begins running in the opposite direction.
If the handle is moved upwards or downwards to the braking zone ('B'), truck will stop. If the release
lever, is automatically moved to the handle braking area ('B'). The truck will start braking.
Belly button switch (14) can prevent accidents and will stop and reverse once the belly button switch
is engaged. If you press this switch, the truck will reverse in opposite direction ('Bw."), then stop to
avoid accidents. If the handle on the operation of the truck is not running, properly, please consider
.
this switch is compressed
5.8. Fault
If there is any fault or truck is not operating properly, please stop using the truck and press the
emergency stop switch (2).
Park the truck in a safe area, turn the ignition off (16) counter clockwise rotation, and then pull out
the key.
Immediately inform the manager and / or contact your customer service personnel. If necessary,
transport the truck with another lifting equipment to a secure location to diagnose.
5.9 In case of emergency
When you encounter an emergency, press down the emergency stop switch (2). All electrical
functions will stop. Keep a safe distance.
6. Battery charging and replacement
1. Only qualified technicians or trained operators should repair or to recharge the battery. Please be
sure to abide by the operation manual and battery manufacturer's instructions.
2. These batteries are maintenance free, prohibited to for re-fill.
3. Battery recycling shall abide by state laws and regulations due to hazardous material and
chemicals. Please abide by these provisions.
4. Treatment of the battery, the prohibition of the use of fire, gas may cause explosion!
5. Battery charging areas should be free from flammable materials or flammable liquids. Smoking is
prohibited, and the area must be well ventilated.
6. Truck must be parked with the equipment with the emergency button off before charging or
installing replacement battery.
7. Before performance maintenance, make sure all wiring harness is connected correctly.
8. The truck is equipped with a sealed liquid acid battery 2*12V/ 100Ah.
9. Only allow the use of sealed lead-acid battery for operation of this truck.
Note: Please consider the maximum operating temperature of the battery.