Appendix
Appendix 3
Using the Digital Clock/Timer as a Count Up Elapsed Timer Only
For applications where the user does not want to use the clock and down count functions, the terminal block can be wired
as shown below. When wired in this manner, the preset time cannot be changed and the alarm will not sound.
CHASSIS
NEUTRAL
120VAC
Appendix 4
Using the Digital Clock/Timer as a Count Down Elapsed Timer Only
For applications where the user does not want to use the clock and up count functions, the terminal block can be wired as
shown below. When wired in this manner, the preset time cannot be changed and the alarm will not sound.
CHASSIS
NEUTRAL
120VAC